page 12
www.CentSys.com
S
ECTION
3
S
PECIFICA
TIONS
3.3. V-Series Controller
Maximum motor current per channel
15A (fused)
Maximum input voltage
14.4V DC
Standby current draw
48mA
Maximum solenoid current draw
2A DC
Maximum auxillary output current
3A (Resettable Electronic Fuse)
Collision detection
Current sense and redundant-optical
Position and trajectory control
Redundant optical
Temperature range
-20°C to +60°C
Onboard receiver type
Code-hopping multichannel
Receiver code storage capacity
64 transmitter buttons
Receiver frequency
433MHZ
TABLE 2
3.5. Power Supply
Nominal input voltage
90V - 240V AC ±10% @ 50/60Hz
AC current draw (maximum)
170mA
Temperature range
-20°C to +60°C
Battery charger output current
(dependant on PSU input voltage)
90V AC input: 1.2A @ 13.8V
240V AC input: 1.8A @ 13.8V
TABLE 3
3.4. Lightning Protection
The
V-Series Controller
utilises the same proven surge protection philosophy that is
used in all our products. While this does not guarantee that the unit will not be damaged
in the event of a lightning strike or power surge, it greatly reduces the likelihood of
such damage occurring. The earth return for the surge protection is provided via the
mains power supply earth. In order to ensure that the surge protection is effective, it is
essential that the unit is properly earthed.