10.
Troubles and
troubleshooting
Troubleshooting on regulations and hydraulics must
be done by an authorised firm
For repairs use only original spare parts
Troubles and troubleshooting
TROUBLE
DESCRIPTION
CAUSE
MEASURE
Boiler does not react
after turn on of main
switcher
Display does not react,
other components do
not work
Boiler is out of power supply
Fuses on bottom plate are off
Vanishing of managing phase
Damage of main fuse ON/ OFF
Provide power supply
Turn on fuses
Check if fuses have three
phases on output
Change damaged part
Boiler does not heat or
insufficiently
heat/heating pump
works
All on display are within
recommended values
but boiler does not
make hot water
Lack of 1 or 2 phases
Small power of boiler
Some relay damaged
Some heater damaged
Check all three phases
Check set power of boiler
Change damaged part
Change damaged part
Boiler heats but it is
very noisy
Higher level of noise
during work
Air in the system
Small water flow
Possible carbonate layer on
heater
Check if the system is air
vented and vent it
Check valves below boiler and
open it
Clean filter below boiler
Take out heaters and clean it
(this is not included in claims
during warranty period)
Boiler turns on quickly
Reaches temperature
too quickly and turns on
Valves below the boiler off
Pump fuse stop to work
Pump jammed
Pump inaccurate
Open valves
Change inaccurate part
Start pump rotor
Change inaccurate part
Great oscillations of
working pressure
Too fast and too big
changes of working
pressure
One valve off
Expansion dish pressure
inadequate
Inaccurate dish
Open the valve
Check pressure in expansion
dish and if needed set dish
pressure adequately
Change inaccurate part
Table
8:
Troubles and troubleshooting
Содержание El-Cm eBasic 12kW
Страница 19: ...Electric connecting Image 12a Boiler electric scheme eBasic with nominal power of 6kW...
Страница 20: ...Electric connecting Image 12b Boiler electric scheme eBasic with nominal power of 9kW and 12kW...
Страница 21: ...Electric connecting Image 13a Boiler electric scheme eBasic with nominal power of 18kW...
Страница 22: ...Electric connecting Image 13b Boiler electric scheme eBasic with nominal power of 24kW...
Страница 23: ...Electric connecting Image 14 Boiler electric scheme eBasic with nominal power of 30kW 36kW and 40kW...