7.3.5 Signal and code of warning and mistakes
☼
Temp.
- slow flashing -
Warning:
lower
limit exceeding (T≤4 °C) or upper limit (T≥85 °C) of temperature of the
heating system
Measure:
Check if valves are open, the functionality of circulation pump and
relay/contactor
☼
Temp.
- quick flashing -
Mistake:
lower limit exceeding (T≤2 °C) or upper limit (T≥89 °C) of temperature of the
heating system
Measure:
Turn off electric power supply for the boiler. Call service
Graphic display of the area of blockade of the boiler work conditioned by temperature (1.temp. increases→ / 2.temp. decreases←)
Mistake signals on display
EL - Mistake:
Very low boiler temperature (T ≤ -9 ° C) or short-circuit temperature sensor - all turned off
Measure:
Turn off power supply. Call service.
EH - Mistake:
Very high temperature (T≥100 °C) not able to display – all turned off
Measure:
Turn off power supply. Call service.
ES - Mistake:
Boiler temperature sensor breaker
– all turned of
Measure:
Turn off power supply. Call service.
Heating installation handling
WORK BLOCKADE
WARNING
NORMAL WORK
NORMAL WORK
WARNING
WORK BLOCKADE
Содержание El-Cm eBasic 12kW
Страница 19: ...Electric connecting Image 12a Boiler electric scheme eBasic with nominal power of 6kW...
Страница 20: ...Electric connecting Image 12b Boiler electric scheme eBasic with nominal power of 9kW and 12kW...
Страница 21: ...Electric connecting Image 13a Boiler electric scheme eBasic with nominal power of 18kW...
Страница 22: ...Electric connecting Image 13b Boiler electric scheme eBasic with nominal power of 24kW...
Страница 23: ...Electric connecting Image 14 Boiler electric scheme eBasic with nominal power of 30kW 36kW and 40kW...