WARNING

!:  If  working  pressure  continues  to 

grow  up  to  3  bar  mechanical  safety  valve  will 
start to leak heating water out of the boiler. 

 

 

 

7.

 

Heating installation handling

 

 
 

7.1

 

Working Instruction

 

 

Safety Instructions 

 

 

Only  adults  familiar  with instructions  and  working mode 
may operate the boiler 

 

Make sure there are no children in the boiler area 

 

Do not dispose or store inflammable materials within safe 
distance of 400 mm round the boiler 

 

Inflammable materials must not be placed on the boiler 

 

User  must  comply  with  instructions  for  operating  the 
boiler 

 

User may only turn on the boiler (except the first start-up), 
adjust temperature on the regulating device and turn off 
the  boiler.  All  other  operations  must  be  performed  by 
authorised service 

 

Authorised person who performed installation is obliged 
to  inform  the  user  about  handling  and  correct  and  safe 
work of boiler 

 

In the event of alert situation, explosion, fire, gas or steam 
leaking, the boiler must not work 

 

Be aware of inflammable characteristics of components 
(Instructions on installations and maintenance) 

 
 
 

7.2

 

Overview of the elements to adjust

 

 

7.2.1  Device functions 

 

  eBasic  is  a  classic  type  of  electric  boiler,  without  a 

circulation pump and expansion vessel. The construction of 
eBasic  is  robust,  and  the  built-in  components  are  of  top 
quality. 

It 

is 

enriched 

with 

microprocessor 

thermoregulator,  which  is  the  most  important  difference 
compared to the previous model. 

  The safety of the device is at the maximum level, because 

a protective circuit is installed - the same as with the "ePlus" 
and "Classic" models 

  Communication  of  the  user,  as  well  as  the  installer 

(servicer) with the device is done through the user interface 
where  you  can  easily  see  and  adjust  all  the  important 
parameters of the device 

  Genuine  software  allows  for  longer  service  life.  The 

microcontroller  continuously  monitors  the  information 
received from the sensor, measures the operating time of 
the  heater,  and  based  on  that  evenly  loads  all  vital 
components 

  Also,  the  microcontroller  monitors  the  dynamic  growth  of 

temperature and based on that and the set power optimizes 
the  engaged  power  of  the  boiler  -  which  means  minimal 
electricity consumption. Energy 

 

7.2.2  Basic adjustments 

 
The  current  temperature  is  continuously  displayed  on  the 
display, indicating the LED that is lit beside the "

Temp

" mark. 

To display other parameters, use the keys 

‘‘▼’’

 and 

‘‘

’’

. In 

addition to the selected parameter whose value is displayed on 
the display, the LED indicator lights up. 
The 

“P”

 key is used to enter the set parameter value (next to 

the  LED).  The  same  key  is  also  used  to  store  the  new  set 
parameter value and exit the setting. 
The parameters that can be set are: 
- '' 

Set temp

 '' - set the temperature  

- '' 

Set powe

r '' - power setting 

 
The temperature can be set in the range of 10 °C to 80 °C, in 
steps of 1 ° C. 
The default power can be set in three steps depending on the 
nominal power of the unit (see table). Turn on / off the heater 
is carried out periodically with a delay of ~ 3 sec, which avoids 
the strike on the power grid. 
 
 

 
 

 

 

For  normal  work  of  this  device  it  is  necessary  to  set 
working  pressure  in  range  between  0.5÷2.0  bar 
(recommendation is 1.0bar) during filling and maintenance 

 
 
 
 
 
 
 
 
 

HT 1:

  Indicates work of heater no. 1 

HT 2:

  Indicates work of heater no. 2 

HT 3:

  Indicates work of heater no. 3 

R.Th.:

 Indicates room thermostat 

Temp:

  Present temperature display [°C]   

Set temp:

  Set temperature display [°C] 

Power:

 Present engaged power [kW] 

Set power:

 Set engaged power [kW] 

 

‘‘

’’

 Button to reduce parameters value and search down 

through Menu 

‘‘

’’

  Button  to  increase  parameters  value  and  search  up 

through Menu 

''P'':

 Button to select parameter 

 

Heating installation handling 

 

Boiler power 

Steps (kW) 

6 kW 

2+2+2 

9 kW 

3+3+3 

12 kW 

4+4+4 

18 kW 

6+6+6 

24 kW 

8+8+8 

30 kW 

6+6+6+6+6 

36 kW 

7,2+7,2+7,2+7,2+7,2 

40kW 

13,33+13,33+13,33 

Image 15:

 Control panel view

 

Table

 6:

 

Power and adjusting steps 

Содержание El-Cm eBasic 12kW

Страница 1: ...Guidebook for installation handling and maintenance ENG El Cm eBasic 6 40kW Electric block boiler for heating systems with thermoregulatory microprocessor FU El Cm eBasic 08 2022...

Страница 2: ...d de blocking 4 7 3 Boiler and installation air emission 5 Electrical connection 5 1 Positions of introducer for the introduction of the power cable 5 2 Connecting power voltage cable 5 3 Scheme for c...

Страница 3: ...assembly All electric works should be performed by authorised person in accordance with corresponding regulations Commissioning and maintenance and repairs should be done by authorised service only Te...

Страница 4: ...o spare parts not delivered by the manufacturer Use only original spare parts Material damages due to freezing When there is damage due to freezing drain water from the boiler tank and pipelines for h...

Страница 5: ...d on regular basis Boiler should be handled only by adults who are familiar with instructions and work of the boiler Do not close safety valve Inflammatory objects must not be put on the boiler surfac...

Страница 6: ...ne polystyrene polyethylene floor fibre materials Table 2 Ignitable materials and composition of elements according to DIN 4102 2 8 Product description Basic components of boiler Boiler body Device fr...

Страница 7: ...cord 6 Terminals for connection neutral N and protective PE lines 7 Connection UN 8 Terminal for room thermostat 9 Microprocessor plate LCTR2 10 Electric heater contactors 11 Temperature sensor 12 Saf...

Страница 8: ...g is damaged during delivery Check if delivery is complete Part Pieces Boiler El Cm eBasic 1 Assembly Set 1 Instructions for handling 1 2 11 Factory plate Factory data plate is placed on the external...

Страница 9: ...2 12 Dimensions and technical data 2 12 1 Dimensions and technical data for boiler El Cm eBasic Image 2 Dimensions El Cm eBasic 6 24kW and 30 40kW Device data El Cm eBasic 6 24kW El Cm eBasic 30 40kW...

Страница 10: ...nimum cable cross section for three phase power supply mm 5 2 5 5 2 5 5 4 5 4 5 6 5 10 5 10 5 16 Needed fuses for single phase supply voltage A 1 32 1 50 Minimum cable cross section for single phase p...

Страница 11: ...carts for bags with tighten strip The product should be in horizontal position during transportation Avoid shocks or collisions Packed boiler put on carts for bags if needed secure it with strip and...

Страница 12: ...ulations and local laws Electric connector should be done according to the connecting plans After corresponding installation of device execute grounding of the plant Before opening device and all work...

Страница 13: ...g or adequate dowel for unusual kind of wall Then screw bolts into delivered dowels or other in such way that are left out from the wall min 5 mm max 10mm Carefully hang device on the wall Make sure t...

Страница 14: ...a manometer so when filling the installation with water the pressure must be monitored on the manometer installed on the heating installation 4 7 1 Filling the boiler with heating water and sealing te...

Страница 15: ...he boiler This device is manufactured for connection to three phase power supply 3N 400 230V 50Hz Only devices with nominal power 6kW and 9kW where the cross section of the connecting cable must be ac...

Страница 16: ...en introducing a power cable into the boiler through any selected set of glands carefully patch the cable to the three pole automatic fuses to avoid damaging the cable sets inside the device Neutral z...

Страница 17: ...remains on for another 2 minutes to remove dissipated heat energy from the heater in case of exceeding the allowed temperature in the boiler the pump also switches on and prevents overheating In gene...

Страница 18: ...W for boiler of 24 40 kW 3 2400W for boiler of 36 kW G4 Heater 3 2000W for boiler of 30 kW 3 2400W for boiler of 36 kW 3 2667W for boiler of 40 kW G5 Heater 3 2000W for boiler of 30 kW 3 2400W for boi...

Страница 19: ...Electric connecting Image 12a Boiler electric scheme eBasic with nominal power of 6kW...

Страница 20: ...Electric connecting Image 12b Boiler electric scheme eBasic with nominal power of 9kW and 12kW...

Страница 21: ...Electric connecting Image 13a Boiler electric scheme eBasic with nominal power of 18kW...

Страница 22: ...Electric connecting Image 13b Boiler electric scheme eBasic with nominal power of 24kW...

Страница 23: ...Electric connecting Image 14 Boiler electric scheme eBasic with nominal power of 30kW 36kW and 40kW...

Страница 24: ...on Prior to turn on check if heating installation is filled with water and air vent Turn on main switcher below device Heating system and device parameters will appear on display Device is adjusted by...

Страница 25: ...rocontroller continuously monitors the information received from the sensor measures the operating time of the heater and based on that evenly loads all vital components Also the microcontroller monit...

Страница 26: ...crease decrease given temperature of the boiler for 1 C Working temperature range is 10 C 80 C Confirmation of change must be done by pressing button P If change is not confirmed 15 sec after pressing...

Страница 27: ...ays for 2 min and temperature measuring indicator will flash quickly image 22 With this temperature value there is danger of freezing and boiler damage so the work of this device will be blocked To co...

Страница 28: ...T 100 C display of its value is not possible to see on the screen so in this will appear code EH meaning that temperature is T 100 C image 26 Measuring temperature indicator will continue to flash qui...

Страница 29: ...Call service Graphic display of the area of blockade of the boiler work conditioned by temperature 1 temp increases 2 temp decreases Mistake signals on display EL Mistake Very low boiler temperature...

Страница 30: ...manufacturer instructions 7 3 7 Heating discontinuity With short time discontinuity of heating working regime the boiler temperature must be decreased using thermo regulator of the boiler To prevent...

Страница 31: ...livered by the manufacturer Control examination log is provided on chapter 8 4 Perform works in accordance with log on control and maintenance All deficiencies remove immediately 8 1 Boiler cleaning C...

Страница 32: ...heck if there is any damage on electric duct lines 6 Check if electric control connections and used elements are fitted tighten it if needed 7 Check thermo regulator on boiler 8 Check function of safe...

Страница 33: ...economy concepts we use only the best technique and materials Packaging Regarding packaging we respect system of recycling which is specific in certain states and which secure optimal recycling All m...

Страница 34: ...amaged Check all three phases Check set power of boiler Change damaged part Change damaged part Boiler heats but it is very noisy Higher level of noise during work Air in the system Small water flow P...

Страница 35: ...indoor LWA indoor dB A 32 35 35 41 41 46 46 46 9 All specific precautions for assembly installation and maintenance are described in the operating and installation instructions Read and follow the ope...

Страница 36: ...hanges that it deems necessary on its products Centrometal d o o Glavna 12 40306 MACINEC HRVATSKA Croatia tel 385 0 40 372 600 email komercijala centrometal hr This document is owned by CENTROMETAL d...

Отзывы: