5.5
Electric schemes of connection
All quoted cross-sections of cables are minimal.
Cross-sections that should be placed depend on
length of the line and placing mode.
Cable cross-sections should be dimensioned according to
local regulations
3P A
Three-pole automatic fuse
DA
Remote power trigger
ST
Safety thermostat (Klixon)
RTH
Room thermostat
RS 1, RS 2, RS 3
Connecting clamps
of room thermostat
WARNING: voltage 5V DC
P1
Main switcher ON/OFF
KON 2
External pump connection connector
RK1, RK2, RK3
Relay contact (for
9,12
and
18
kW)
K1 ÷ K6
Contactor (for
24,30
and
36
kW)
G1
Heater
-3×1500W for boiler of:
9
kW
-3×2000W for boiler of:
12
,
18,30
kW
-3×2667W for boiler of:
24, 40
kW
-3×2400W for boiler of:
36
kW
G2
Heater
-3×1500W for boiler of:
9
kW
-3×2000W for boiler of:
6,12
,
18,30
kW
-3×2667W for boiler of:
24, 40
kW
-3×2400W for boiler of:
36
kW
G3
Heater
-3×2000W for boiler of:
18,30
kW
-3×2667W for boiler of:
24, 40
kW
-3×2400W for boiler of:
36
kW
G4
Heater
-3×2000W for boiler of:
30
kW
-3×2400W for boiler of:
36
kW
-3×2667W for boiler of:
40
kW
G5
Heater
-3×2000W for boiler of:
30
kW
-3×2400W for boiler of:
36
kW
-3×2667W for boiler of:
40
kW
LCTR 2
Microprocessor thermoregulator
OS 1
Electric fuse 230V T500mA
OS 2
Electric fuse 230V T2A
OS 3
Electric fuse 24V T500mA
OS 4
Electric fuse 8V T500mA
KON1
Supply connector (230V AC)
K 102
Temperature sensor connection
TS
Temperature sensor
K 105
Interface connection (LCI2)
K 106
Room thermostat connection (RTH)
RE 1
-Relay 1/3 heater (for 6 kW boiler)
-Relay switches RK1 (9, 12 and 18kW)
-Relay for switching K1 (24kW)
-Relay for switching on K1 and K2 (30,
36 and 40kW)
RE 2
-Relay 1/3 heater (for 6 kW boiler)
-RK2 switching relays (9, 12 and 18kW)
-Relay for switching K2 (24kW)
-Relay for switching on K3 and K4 (30,
36 and 40kW)
RE 3
- Relay 1/3 heater (for 6 kW boiler)
- Relay for switching RK3 (9, 12 and
18kW)
- Relay for switching K3 (24kW)
- Relay for switching K5 and K6 (30, 36
and 40kW)
Electric connecting
Legend
Legend
Table 4:
Legend of connecting schemes
Содержание El-Cm eBasic 12kW
Страница 19: ...Electric connecting Image 12a Boiler electric scheme eBasic with nominal power of 6kW...
Страница 20: ...Electric connecting Image 12b Boiler electric scheme eBasic with nominal power of 9kW and 12kW...
Страница 21: ...Electric connecting Image 13a Boiler electric scheme eBasic with nominal power of 18kW...
Страница 22: ...Electric connecting Image 13b Boiler electric scheme eBasic with nominal power of 24kW...
Страница 23: ...Electric connecting Image 14 Boiler electric scheme eBasic with nominal power of 30kW 36kW and 40kW...