WARNING:
Material damage due to
overheating
7.3.4 Warning with high temperature
If temperature of the system increases to T≥85°C, the pump
works continually (due to taking heating energy through pipe
routing network), but measuring temperature indicator starts to
flash
slowly
(image 24). It is necessary to decrease
temperature to T≤84°C in order to stop automatic flashing of
warning indicator and continue with normal work of boiler.
If temperature of the system increases to T≥89°C, the pump
works continually (due to taking heating energy through pipe
routing network), but measuring temperature indicator starts to
flash
quickly
(image 25). It is necessary to decrease
temperature to T≤88°C in order to stop automatic flashing of
this mistake warning indicator.
If temperature increases to T≥100 °C, display of its value is not
possible to see on the screen so in this will appear code
EH
meaning that temperature is T≥100 °C (image 26). Measuring
temperature indicator will continue to flash
quickly
.
In this case it is necessary to turn off this device out of electric
power supply and call authorised service to establish and
remove the cause of problem.
If temperature sensor is damaged (or disconnected), the code
ES will appear on the screen meaning ''Error temperature
Sensor'' (image 27). Temperature measuring indicator will
continue to flash
quickly
.
In this case it is necessary to turn off this device out of electric
power supply and call authorised service to establish and
remove the cause of problem.
Heating installation handling
Image 24:
Warning
– Temperature close to restricted
high temperature value
Image 25:
Blocked work of the heaters due to danger
of thermic overload, pump work continually
Image 26:
Temperature above 99 °C
Image 27:
Temperature sensor in discontinuity
Содержание El-Cm eBasic 12kW
Страница 19: ...Electric connecting Image 12a Boiler electric scheme eBasic with nominal power of 6kW...
Страница 20: ...Electric connecting Image 12b Boiler electric scheme eBasic with nominal power of 9kW and 12kW...
Страница 21: ...Electric connecting Image 13a Boiler electric scheme eBasic with nominal power of 18kW...
Страница 22: ...Electric connecting Image 13b Boiler electric scheme eBasic with nominal power of 24kW...
Страница 23: ...Electric connecting Image 14 Boiler electric scheme eBasic with nominal power of 30kW 36kW and 40kW...