If the Thermostat does not have the terminal markings listed, it will be necessary to
contact the Thermostat manufacturer to advise the correct terminal mapping.
Once the wires are connected to the NT,
connect power to the cooling unit, and turn “on”
the power on the cooling unit’s digital display. The current temperature will show on
the digital display. There is a 3-minute delay before the cooling unit will start to run.
Activate the NT and begin initial set up.
Recommended Settings
The following guidelines are general recommendations to optimize the NT for wine cellar
applications. It will be necessary to reference the available NT menus and available
options from the documentation provided with t he NT.
•
Set the mode to “Cool Only”
•
Disable all scheduling, learning, and occupancy tracking functions. These routines
are intended for comfort cooling and are not suitable for long term wine storage
applications.
•
If the Thermostat has a configurable minimum/maximum set point range, set the
minimum to 47°F (or as low as possible) and set the maximum set point to 62°F.
This is the safe operating range for CellarPro cooling units.
•
Enter the desired cellar set point temperature. The NT will control the cooling
unit to manage this set point temperature.
•
Set fan to “Auto”.
•
Compressor Minimum Off Time: If this setting is disabled by default, it must be
enabled, with a minimum off time for CellarPro products of 3 minutes.
•
If the Thermostat allows high/low temperature alarms, we recommend the
following settings: 40°F (Low) and 70°F (high).
•
If the Thermostat has an adjustable temperature differential (cooling on/off
range), a setting of 4°F is recommended. Many Thermostats have a tight fixed
differential of 1-2°F. In this case the cooling unit will cycle more frequently than
recommended. Therefore, it is advisable to set a longer Compressor Minimum Off
Time to minimize frequent cycling.
•
If the NT
has a “Change Air Filter” reminder, set the reminder for every
3 months.
This is for inspection and cleaning or replacement of the condenser filter.
•
Humidity Management (with Ecobee4 Pro Thermostats:) The humidity level in the
cellar can be maximized by allowing the cooling fans to run at the end of every
cooling cycle
Содержание 2000VSi
Страница 1: ...V4 18 ControltheElements Owner sManual 2000VSi 2000VSx...
Страница 2: ...V4 18 This page intentionally left blank...
Страница 6: ...6 V4 18 2000VSi Cut Sheet...
Страница 7: ...7 V4 18 2000VSi Cut Sheet As Ducted...
Страница 8: ...8 V4 18 2000VSx Cut Sheet...
Страница 15: ...15 V4 18 2000VSi Mounting Diagrams...
Страница 16: ...16 V4 18 2000VSx Mounting Diagrams...
Страница 23: ...23 V4 18...