17
V4.18
•
Installation Notes:
1.
The unit is shipped with (4) wall mounting brackets, a 1/2" OD drain stub, a tube clamp, an
d a 10’
length of 1/2
” I.D. condensate drain line. The required hardware is shipped loose with the unit.
a.
Model 2000VSi (indoor installations): Select the desired set of mounting holes, location #1,
#2, or #3 (shown above). The mounting brackets can be used on either side of the wall.
b.
Model 2000VSx (outdoor installations): The rear cover uses hole location #1. If this is also
the desired location for the mounting brackets, first make certain the rear cover is in place,
and then install the mounting brackets over the rear cover.
2.
If the mounting brackets are used on the outside of the cellar in Location 1, a shelf will be needed
to support the weight of the cooling unit.
3.
To attach the mounting brackets, attach the side and top brackets to the unit using (6) #8 x 5
/8”
sheet metal screws. The top and bottom brackets only attach to the side brackets
–
there are no
mounting holes for the top and bottom mounting bracket in the case of the cooling unit. Secure
the top and bottom brackets to the side brackets with (4)
1/4”
-20 x 5/8
”
bolts and lockwashers
(included).
4.
Attach insulated foam tape to the mounting brackets on the side that will face the wall to create
an insulated and airtight seal between the wall and the brackets.
5.
Once the cooling unit is installed, all cracks and gaps between the cooling unit and the cellar
should be sealed. A complete and proper seal must be made between the cellar and the cooling unit
to ensure that outside air does not enter the cellar. Use sealant tape or caulking to seal the perimeter
where the cooling unit touches the cellar. Check the seal by having a helper stand in front of the cabinet
while you shine a flashlight around the cooling unit edges to discover any gaps in sealant.
6.
Slide the drain tubing over the overflow connection and secure tightly with the provided tube
clamp. Run the overflow drain tube to a gravity drain, routing so that the tube forms a water
trap near the unit. Charge the tube trap with water.
Содержание 2000VSi
Страница 1: ...V4 18 ControltheElements Owner sManual 2000VSi 2000VSx...
Страница 2: ...V4 18 This page intentionally left blank...
Страница 6: ...6 V4 18 2000VSi Cut Sheet...
Страница 7: ...7 V4 18 2000VSi Cut Sheet As Ducted...
Страница 8: ...8 V4 18 2000VSx Cut Sheet...
Страница 15: ...15 V4 18 2000VSi Mounting Diagrams...
Страница 16: ...16 V4 18 2000VSx Mounting Diagrams...
Страница 23: ...23 V4 18...