Page 8 | 1-800-343-9463
WM&FD TWIN
051019
WALL-MOUNTED TWIN SPECIFICATIONS
Evaporator unit
Model
9000 Master Evaporator
(Fan Coil Unit)
9000 Slave Evaporator
(Fan Coil Unit)
Cellar Size
Approx. 3000 cu. ft., provided cellar is fully insulated and sealed with proper vapor barrier*
BTU/h w/85°F air entering
condenser coil
7850
7850
Dimensions
16.1”L x 20.5”W x 15.5”H
16.1”L x 20.5”W x 15.5”H
Refrigerant
R-134a
R-134a
Voltage Rating
115V (15-amp dedicated circuit required)
115V (15-amp dedicated circuit required)
Weight (lbs)
60
60
Amps
Evaporator: 1 running amp (per unit)
Compressor: LRA 35, RLA 6.5
Evaporator: 1 running amp (per unit)
Compressor: LRA 35, RLA 6.5
Line Set
Liquid line 3/8”; suction line 3/4” (less than 50 ft.), 7/8” (greater than 50 ft.)
Drain Line
1/2” ID clear plastic tubing (not provided)
Installation
Evaporator units are installed in the cellar.
Thermostat
Advanced digital display (50-ft. cable), liquid-temperature-measuring bottle probe (50-ft. cable)
Temp. Delta
Can maintain a 55°F temperature differential with up to 110°F condenser air intake temperature
Warranty
Two-year limited warranty (parts and labor)
*Each cellar is unique and has specific cooling requirements. Heat load calculations should always be performed prior to selecting a cooling unit.