www.cellarcool.com | Page 9
WM & FD Twin
FULLY DUCTED TWIN SPECIFICATIONS
Duct plenum
Return air
Supply air
Model
9000 Master Evaporator
(Fan Coil Unit)
9000 Slave Evaporator
(Fan Coil Unit)
Cellar Size (cu. ft.)
Approx. 3000 cu. ft., provided cellar is fully insulated and sealed with proper vapor barrier*
BTU/h w/85°F air entering
condenser coil
7000
7000
Dimensions
20.1”L x 20.5”W x 15.5”H
20.1”L x 20.5”W x 15.5”H
Refrigerant
R-134a
R-134a
Voltage Rating
115V (15-amp dedicated circuit required)
115V (15-amp dedicated circuit required)
Weight (lbs)
60
60
Amps
Evaporator: 1 running amp (per unit)
Compressor: LRA 35, RLA 6.5
Evaporator: 1 running amp (per unit)
Compressor: LRA 35, RLA 6.5
Line Set
Liquid line 3/8”; suction line 3/4” (less than 50 ft.), 7/8” (greater than 50 ft.)
Duct Size
8” supply, 10” return (x2)
Drain Line
1/2” ID clear plastic tubing (not included)
Installation
Evaporator units can be installed up to 25 ducted feet away.
Thermostat
Advanced digital display (connected to master unit) with 50-ft. cable; liquid-temperature-measuring
bottle probe (also with 50-ft. cable)
Temp. Delta
Can maintain a 55°F cellar temperature with up to 110°F condenser air intake temperature
Warranty
Two-year limited warranty (parts and labor)
*Each cellar is unique and has specific cooling requirements. Heat load calculations should always be performed prior to selecting a cooling unit.