9. VERSIONS
ADA-14110 -
-
-
Order example:
Product Symbol:
ADA-14110-1-1-3
1
– basic version of electronic,
1
–
non galvanic isolation,
3
–
cover without inlets, plug-in screw terminal block,
Electronic versions:
Basic
1
Galvanic isolation of RS232 interface:
No isolation – transmitted signals of
RS232: Tx, Rx, RTS, CTS, DTR, DSR,
DCD, GND .
1
1kV DC – transmitted signals of RS232:
Tx, Rx, RTS, GND .
2
3kV DC – transmitted signals of RS232:
Tx, Rx, RTS, GND .
3
Terminal & Terminal Cover:
Cover without inlets, screw terminal block
1
Cover with inlets, screw terminal block
2
Cover without inlets, plug-in screw terminal block
3
10. SPECIFICATION
TECHNICAL DATA
Transmission Parameters
Interface
Wi-Fi (802.11b)
RS232
Connector
SMA–plug + Antenna
DB-9M (Mail)
Max. number of connected device
Depend on type of network addressing
1
Max. baud rate
11 Mbit/s
230,4 kbps
Standards
IEEE 802.3, IEEE 802.11b (2.4GHz)
EIA-232, CCITT V.24
Max. Line length
- inside building – from 30m to 150m,
- open area up to 300m,
- open area with use of additional antenna - up to
8000m.
Up to 15 m
Transmission line RS232
CAB-DB9F/DB9M-S-1,8m cable
Transmission type
Asynchronous full duplex, half duplex.
Optical Signalization
•
PWR green LED – power supply,
•
RX red LED - receive data on RS232 port,
•
TX yellow LED - transmit data on RS232 port,
•
RTS yellow LED – outgoing signal on RS232 port,
•
CTS red LED - incoming signal on RS232 port, (version without isolation),
•
CTS red LED - incoming signal on RS232 port, (version without isolation),
•
DTR yellow LED – outgoing signal on RS232 port, (version without isolation),
•
DSR red LED - incoming signal on RS232 port, (version without isolation),
•
DCD red LED - incoming signal on RS232 port, (version without isolation),
Electrical Parameters
Power requirements
10 - 24 – 30 V DC
Power Cable
Recommended length – up to 3m
Power
4 W
Protection from reverse power polarization
Yes
Galvanic Isolation
1kVDC or 3kVDC 2-WAY depend on version
Optoisolation
~3kVDC between interfaces Wi-Fi and RS232
Electromagnetic compatibility
Resistance to disruptions PN-EN 55024.
Emission of disruptions PN-EN 55022 A class.
PN-EN 301 489-3 v1.4.1:2006, PN-EN 300 328 v1.7.1:2007.
Safety requiring
According to the PN-EN60950 norm.
Environment
Commercial and light industrial. Devices A class.
Environmental Parameters
Operating temperature
-30 ÷ 50°C
31
ADA-14110