5.2.2.1.2.2. THE 'ENABLE TCP KEEP-ALIVE' OPTION CONFIGURATION
Option
Enable TCP Keep-Alive
keeps connection between server and client, even if the data is not transmitted over the network and
reconnection in case of interruption.
Configuration of this option can be made by selection
Configuration > Network > Advanced Network Settings > TCP Keep-Alive
Settings.
In this section can be configured:
–
Idle Time
– specifies the period of time (scope 10 sec. - 24 hours) that a TCP connection has to be idle before a keep-alive is sent.
–
Probe Interval
– the time in seconds between each keep-alive probe (scope 10 – 75 sec.),
–
Probe Count
– the number of times TCP probes the connection to determine (scope 5 – 30 trials).
5.2.2.1.2.3. SERIAL PORT TRANSMISSION PARAMETERS CONFIGURATION
For proper operation of the ADA-14110 wireless serial server with device connected to his RS232 serial port, should be set the same
transmission parameters for both devices.
Select
Basic Serial Settings
and enter
Baud Rate
,
Data Bits
,
Parity
,
Stop Bits,
the same parameter like has device connected to
the serial port of the ADA-14110.
5.2.2.1.3. UDP SOCKETS CONFIGURATION
Choosing
UDP Sockets
is configured the serial port of the ADA-14110 for direct communication with PC or other device connected to
the network by the use of UDP socked. Data sending by application or other device/s to this port are transferred through
WLAN/LAN/WAN to the ADA-14110 and are present on his serial port. Press [
Apply
] for save the configuration
5.2.2.1.3.1. UDP CLIENT & SERVER CONFIGURATION IN CASE OF MASTER DEVICE
After saving the UDP Sockets profile, will open section
UDP Server Settings
with operating parameters like on picture below. Set an
access to UDP server on e.g. 2101 port. Then select
Automatically send serial data
in section
UDP Client Settings
, this
automatically send received data by the use UDP client service to the SLAVE device connected to LAN/WAN through e.g. ADA-13020,
ADA-13028L, ADA-13040MG, ADA-13110, ADA-14040, ADA-14110.
On the lists
Send data to the following network services
are addresses of network devices and ports to which will be send data. In
field:
–
Description
- enter e.g. location of the serial server and SLAVE device,
–
Send To
- enter IP address of e.g. serial server, connected to SLAVE device,
–
UDP Port
- enter the number of port on which is working UDP Server of the serial server connected to SLAVE device and press
[Add]
In the section
Send data under any of the following conditions,
is recommended to set parameters like on picture bellow.
For saving the configuration of UDP client and server for MASTER device, press
[Apply]
.
19
ADA-14110