Ceiec Electric Technology
20
This option exists in both the On-Line and Off-Line programming modes.
Click on Channel Settings under Channel Management on the left-hand pane and the following
screen appears.
Double-click on a particular channel
or click
on the right to modify the channel settings. The
Edit dialog box is shown below.
Basic Settings
Option
Description
Setting
Enable
Checked if the Channel is enabled
Enabled by default
Description
Channel description
Default = “Channel X”
Channel
Channel 1 to 16 can be set as Serial or
Ethernet, channel 17 to 20 can only
be set as Ethernet
Serial, Ethernet
Channel 1 to 16 = Serial*
Channel 17 to 20 = Ethernet*
Channel Config.
Configure a Channel to be a Modbus
Master or Transparent
ModbusMaster*, Transparent
*Default
Notes:
1)
Channel Config is reset to their default values when Channel is changed.
2)
Click <Submit> at the upper left-hand corner of the right-hand pane to store the new
configuration in a local cache before leaving this page.