Ceiec Electric PMC-1380-3 Series Скачать руководство пользователя страница 1

 

 

PMC-1380-3 

Communications Processor 

User Manual 

  Version: V3.2A

 

30/03/2015 

 

 
 
 
 

 

Ceiec Electric Technology 

Содержание PMC-1380-3 Series

Страница 1: ...PMC 1380 3 Communications Processor User Manual Version V3 2A 30 03 2015 Ceiec Electric Technology...

Страница 2: ...Ceiec Electric Technology CET The information contained in this manual is believed to be accurate at the time of publication however CET assumes no responsibility for any errors which may appear here...

Страница 3: ...evice to ensure that it is equipped with the appropriate power supply Under no circumstances should the device be connected to a power source if it is damaged Make sure the device is mounted to a well...

Страница 4: ...not accept liability for any damage caused by device malfunctions CET accepts no responsibility for the suitability of the device to the application for which it was purchased Failure to install set...

Страница 5: ...al Applications 13 Chapter 4 Configuring the PMC 1380 3 via the Web Console 16 4 1 On line Web Console Login 16 4 2 Off line Web Console Login 17 4 3 Network Settings 18 4 4 Time Settings 19 4 5 Chann...

Страница 6: ...lave IEDs at pre defined intervals and implementing data caching for simultaneous access by multiple master applications via Modbus TCP connections The PMC 1380 3 comes with Tx Rx LEDs for the serial...

Страница 7: ...eiec Electric Technology 7 Additional information is available from CET via the following sources Visit www cet global com Contact your local representative Contact CET directly via email or telephone...

Страница 8: ...nel 2 2 Mounting The PMC 1380 3 should be installed in a dry environment with no dust and kept away from heat radiation and electrical noise source Installation steps Fit the device through the cutout...

Страница 9: ...the negative wire to the N terminal Figure 2 4 Power Supply Connections 2 4 Chassis Ground Wiring Installation Connect one end of the ground wire to the Chassis Ground terminal on the PMC 1380 3 usin...

Страница 10: ...reen Pin 7 Brown White Pin 7 Brown White Pin 8 Brown Pin 8 Brown Figure 2 7 Straight through Connection 2 5 2 Cross over Connection A cross over RJ45 cable should be used if the PMC 1380 is connected...

Страница 11: ...85 Pin Definition Pin RS 232 Description 1 NC No Connect 2 RxD Receive Data 3 TxD Transmit Data 4 NC No connect 5 GND Ground 6 NC No connect 7 NC No connect 8 NC No connect 9 NC No connect Pin RS 485...

Страница 12: ...and Esc Use the and buttons to navigate the menu system Use the Enter button to enter into a sub menu and the Esc key to return to the previous menu 3 1 4 LCD Display The LCD display on the PMC 1380...

Страница 13: ...k Gateway Change Password Set Clock Contrast Setup Figure 3 2 Main Menu 3 2 Typical Applications The PMC 1380 3 is an ideal instrument to connect serial devices to an IP based Ethernet LAN for any ind...

Страница 14: ...s typically used in smaller applications where there is only a single networking backbone This networking topology features a simple structure that is easy to maintain cost effective and suitable for...

Страница 15: ...ted at the application level in the event that the main backbone fails The dual Ethernet configuration is slightly different from the true redundant configuration where in the case of a true redundant...

Страница 16: ...The Internet Options window appears Select the Security tab and then click on the Custom Level button near the bottom of the window The Security Settings window appears Enable the three options as sh...

Страница 17: ...Password The default user name is user and the default password is 123456 4 2 Off line Web Console Login To run the PMC 1380 3 Off Line Web Console first install the program by double clicking the PM...

Страница 18: ...3 in LAN to choose Enter Enter the selected configuration page 4 3 Network Settings This option exists in both the On Line and Off Line programming modes Click on Network under Device Settings on the...

Страница 19: ...Source Select the clock source for Time Sync RTC Internal RTC GPS GPS inputs SNTP Simple Network Time Protocol Default RTC Server IP Specify the SNTP Server s IP address Default 127 0 0 1 Time Sync In...

Страница 20: ...if the Channel is enabled Enabled by default Description Channel description Default Channel X Channel Channel 1 to 16 can be set as Serial or Ethernet channel 17 to 20 can only be set as Ethernet Ser...

Страница 21: ...e Odd Even Mark Space Stop Bits Select the number of Stop Bits 1 2 IP Port Specify the IP port number that corresponds with the Channel 1 to 65535 Response Timeout s The TCP IP connection will be rele...

Страница 22: ...0 Time Sync Interval Select how often the Time Sync Packets are sent 0 to 60000 s Default 300 Loop Delay Time delay between successive scans of the entire loop of Slave IEDs 0 to 60000 s Default 0 Re...

Страница 23: ...local cache before leaving this page 3 Click Save at the upper right hand corner of the web page to save the new configuration to the device s configuration file that is stored on the PC for Off Line...

Страница 24: ...per right hand corner of the web page to save the new configuration to the device s configuration file that is stored on the PC for Off Line programming or to download the new configuration to the PMC...

Страница 25: ...leave the PMC 1380 3 Web Console Please ensure that your changes have been saved before leaving 4 8 Data Cache Management This option exists in both the On Line and Off Line programming modes Click on...

Страница 26: ...01 00 etc 0 1 5 10 15 20 30 60 Default 0 Disable Notes 1 PMC 1380 3 supports up to 16 TCP connections for Client access over Ethernet 2 Click Submit at the upper left hand corner of the right hand pan...

Страница 27: ...Parameter name IED Description View only IED name Channel Description The Channel to which a parameter belongs Notes 1 The maximum no of AI in each Data Cache is 2048 2 The maximum no of DI in each D...

Страница 28: ...d pane and the following screen appears Click Submit and then Save to save your changes after modification Option Description Setting Old User Name Enter the old user name Old Password Enter the old p...

Страница 29: ...onsole PMC 1380 Download the complete configuration from the Web Console to the connected PMC 1380 3 Discover PMC 1380 Discover if there are any PMC 1380 3 devices on the LAN and list their IP address...

Страница 30: ...gramming 3 Click Quit to leave the PMC 1380 3 Web Console Please ensure that your changes have been saved before leaving 4 13 Statistics This option only exists in the On Line Web Console Click on Sta...

Страница 31: ...your changes will be lost 4 15 Reboot This option only exists in the On Line Web Console Click on Reboot under System Maintenance on the left hand pane and the following screen appears Any configurat...

Страница 32: ...Ceiec Electric Technology 32...

Страница 33: ...nk Act Green Ethernet Connection Indication Network Activity Indicator 100Mbps Yellow 100 Mbps Connection Indication Rx Green Receive Activities Tx Yellow Transmit Activities Power Supply L N GND Stan...

Страница 34: ...elds IEC 61000 4 3 2008 Level III Fast Transients IEC 61000 4 4 2004 Level IV Surges IEC 61000 4 5 2005 Level IV Conducted Disturbances IEC 61000 4 6 2008 Level III Magnetic Fields IEC 61000 4 8 2009...

Страница 35: ...uide Contact us Ceiec Electric Technology Headquarters 8 F Westside Building 201 Terra Industrial Tradepark Che Gong Miao Shenzhen Guangdong P R China 518040 Tel 86 755 8341 5187 Fax 86 755 8341 0291...