CCH® Elite Plus Operation and Installation Manual (Model CCH1-HCE) Rev 1.0 3/2020
23
10 Appendix
10 .1
Requirements and Specifications
10.1.1
Requirements for Product Installation and Operation
Table 5. Site Requirement
Recommended Clearance
Feeder: 48" L x 48" W x 76" H [121.9 cm x 121.9 cm x 193.0 cm]
Minimum Clearance
Feeder: 36" L x 36" W x 64" H [91.4 cm x 91.4 cm x 162.6 cm]
Water Inlet
2.5 - 3.5 gpm [9.5 - 13.2 lpm] @ 30 - 40 psig [2.1 - 2.8 bar]
Electrical
120/240 V AC, 1 ph, 50/60 Hz, 15 - 20 A
Table 6. Accessory Requirements
Chemical
CCH® Tablets for Industrial Applications and Swimming Pools
or
CCH® Elite Tablets
Discharge Tubing
1/2” [1.27 cm] OD Polyethylene flexible tubing
Water Inlet Tubing
1/2” [1.27 cm] OD Polyethylene flexible tubing
10.1.2
Product Specifications
Table 7. Operational Specifications
Dry Chemical Capacity
90 lbs + 45 lbs reserve [40.8 kg + 20.4 kg reserve] (91.8 lbs [41.6 kg] of available chlorine
Tank Size (Solution Volume)
10.3 gal [39.0 L]
Available Working Solution
4.8 gal [18.2 L]
Water Inlet Size
1/2" [1.3 cm] OD
Solution Outlet
1/2" [1.3 cm] OD
Shipping Weight
Approximately 70 lbs [31.8 kg]
Operating Weight
Approximately 220 lbs [100 kg]
Operating Temperature
40 0F – 95 0F [4.4 0C – 40.6 0C]
Dimensions
29.8" L x 25.3" W x 40.9" H [75.7 cm x 64.3 cm x 103.9 cm]
Table 8. Chemical Feed Rate Specifications
Chlorine Delivery Rate (Pools)
5 – 125 lbs [2.3 kg – 56.7 kg] AvCl/day
Maximum of 5.2 lbs [2.4 kg] AvCl/hr
Chlorine Delivery Rate (Spas)
5 – 125 lbs [2.3 kg – 56.7 kg] AvCl/day
Maximum of 5.2 lbs [2.4 kg] AvCl/hr
Solution Strength
0.6 – 0.8% at 84 0F [28.8 0C] inlet water temperature
Venturi Discharge Rate
3 gpm [11.4 lpm] at nominal venturi operation