CCH® Elite Plus Operation and Installation Manual (Model CCH1-HCE) Rev 1.0 3/2020
21
10.
Place the used basket and drain pipe into the FRESH WATER bucket.
11.
Shake the used basket up and down in the FRESH WATER bucket to remove loose residue.
12.
Transfer the used basket and drain pipe to the ACID FOR SOAKING bucket and let it soak for 24 hours.
13.
Remove the venturi from the union connection and place it in the ACID for soaking bucket and let it soak for 1 hr.
14. Pour the contents of the RINSE ACID bucket into the hopper of the feeder.
15. After 1 hour, check the chlorinator and tank. If both are still heavily scaled:
a.
Carefully pour another 32 oz of muriatic acid into the hopper.
b. Add 32 oz of clean water to the hopper.
c. Check the chlorinator and tank again in another hour.
16.
After 1 hour, check the venturi. If it is still scaled, add some more acid and water in the soaking bucket and allow to soak for another 30 min
to 1 hour. Once the venturi is confirmed clean, re-install at the 1 ½" unions.
17. After the feeder is clean, open the 1/2" outlet ball valve on the venturi suction allowing it to remove the contents of the tank.
18. Inspect the hopper and solution tank for cleanliness.
19.
Pour additional fresh water into the hopper, if necessary, to remove any debris remaining in the hopper or tank.
20.
After the feeder has drained, close the outlet 1/2" ball valve.
21.
Dry the inside of the hopper.
22.
Install the replacement basket and drain pipe and place CCH® tablets into the hopper.
23.
Follow the Operation Instructions on page 16 to restart the unit.