CCH® Elite Operation and Installation Manual (Model CCH1-HCE) Rev 1.0 3/2020
12
1.
Refer to Appendix section 10.2.1 and 10.2.2 for control box wiring help.
2.
Remove the booster pump motor end cover to expose the pumps dual-voltage selector.
3.
If you have 230 V motor supply voltage, confirm that the plug is set for 230 V. The arrow on the plug will point to the 230 V position, which
is the default position of the pump (the plug only connects with one prong in this position).
4. If you have 115 V supply, pull the plug straight up and place it on the two brass prongs so that the arrow points to the 115 V position.
5. Open the control box cover and wire the booster pump to the control box using the wiring diagram, Figure 5.
6.
Replace the booster pump motor end cover to complete the booster pump wiring.
5 .7 Connect the Flow Switch Cable
Connect the orange flow switch cable to the flow switch:
1.
Route the flow switch cable so that it is not a tripping hazard.
2.
The M12 connector on the cable goes in one direction. Screw in the connector so that it fully engages with the flow switch.
5 .8 Prime the System
1.
Allow pool water to enter the 1 ½" and 1/2" piping and tubing to confirm overall water tightness.
2.
Open the 1 ½" inlet ball valve and allow water to enter the booster pump checking for leaks.
3.
Slowly crack open the booster pump discharge union, allowing water to flow out confirming that the booster pump is fully primed.
4. Reconnect and tighten the discharge union.
5. Open the 1 ½" outlet ball valve fully priming the entire booster pump / venturi loop.
6.
Open the 1/2" gray inlet and outlet feeder ball valves, allowing water to reach the feeder.
7. Check for leaks at the booster pump and venturi loop and feeder and flow switch. Redo any leaking connections.