4. Prepare the soak bucket:
a.
Carefully add 12 oz of muriatic acid to one of the 5-gallon buckets to create a roughly 1% solution of 20 Baume muriatic acid.
Warning:
Always be careful when adding muriatic acid to water; this combination creates an
exothermic reaction, which gives off heat. Failure to take care may result in serious
injury.
b. Label this bucket "ACID" and set it aside so that it will not be knocked over.
5. Label the remaining bucket "FRESH WATER" and set it aside.
6.
Close the feeder inlet and outlet 1/2” ball valves.
7. Turn off the control box master power switch.
8. Use basket removal tool to remove the used grid basket from the chlorinator. If necessary, use a flat head screw driver to pry and jostle the
basket to break scaling.
9.
If necessary, break off excess scale off of the HCE Bowl 450 cut drain pipe.
10.
Pour any remaining CCH® tablets into the replacement basket and install the basket and chemical into chlorinator.
11.
Place the used basket into the FRESH WATER bucket.
12.
Slowly open the inlet manifold ball valve.
13.
Turn on the control box master power switch.
14. Shake the used basket up and down in the FRESH WATER bucket to remove loose residue.
15. Transfer the used basket to the acid bucket and let it soak for 24 hours.
8.2.3
Comprehensive (Offline) Cleaning Instructions
Warning:
Always label the contents of cleaning buckets.
1.
If possible, allow the hopper to run completely out of CCH® tablets.
2.
Add water to three 5-gallon buckets until each bucket is approximately 3/4 full.
3.
Prepare the soak bucket:
a.
Carefully add 12 oz of muriatic acid to one of the 5-gallon buckets to create a 1% solution of muriatic acid.
Warning:
Always be careful when adding muriatic acid to water; this combination creates an
exothermic reaction, which gives off heat. Failure to take care may result in serious
injury.
b. Label this bucket "ACID FOR SOAKING" and set it aside so that it will not be knocked over.
4. Prepare the rinse bucket:
a.
Carefully add 32 oz of muriatic acid to another 5-gallon buckets.
Warning:
Always be careful when adding muriatic acid to water; this combination creates an
exothermic reaction, which gives off heat. Failure to take care may result in serious
injury.
b. Label this bucket "RINSE ACID" and set it aside so that it will not be knocked over.
5. Label the remaining bucket "FRESH WATER" and set it aside.
6.
Close the booster pump and venturi inlet and outlet 1 ½" ball valves.
7. Close the feeder inlet and outlet 1/2” ball valves.
8. Turn off the control box master power switch.
9.
Remove the drain pipe from the HCE bowl and use the basket removal tool to remove the used grid basket from the chlorinator. If
necessary, use a flat head screw driver to jostle the basket to break scaling.