1220C GB 19991004
3
Check that the infrared tubes in the dryer assembly light during the dryer fan cy-
cle.
– This can be viewed by removing the processor cover and dryer assembly cover.
– To momentarily check the infrared tubes, depress the interlock switch with a pencil or
a screwdriver.
Chemical / Fixer replenishment
1
Check that the fixer is not exhausted.
– If the tanks have not been cleaned according to the weekly cleaning schedule (refer to
chapter 3, ‘Cleaning the Cawomat 2000 IR’), drain and clean the fixer tank and the re-
plenishment bottle.
– Replace the fixer tank, mix a new solution in the replenishment bottle and reinsert it in
the processor. The tank will be filled automatically.
– Check for proper film drying by running an exposed test film.
2
If the processor has been idle for more than one day, the fixer may have to be
replenished.
Depress the manual replenishment key to initiate a replenishment cycle of 3 minutes. The
indicator light should remain illuminated and the replenishment pump motor should oper-
ate at double speed.
60
Advanced service
5
INSTRUCTIONS FOR SKILLED SERVICE PERSONNEL ONLY
1220C Cawomat 2000 IR RM 07-10-99 14:19 Page 60
Содержание 2000 IR
Страница 1: ...CAWOMAT 2000 IR Reference manual Cawomat 2000 IR 1220C Cawomat 2000 IR RM 07 10 99 14 17 Page p1...
Страница 5: ...Preface Introducing the Cawomat 2000 IR 1220C Cawomat 2000 IR RM 07 10 99 14 17 Page 1...
Страница 6: ...1220C GB 19991004 2 Preface 0 1220C Cawomat 2000 IR RM 07 10 99 14 17 Page 2...
Страница 12: ...1220C GB 19991004 8 Installation 1 1220C Cawomat 2000 IR RM 07 10 99 14 17 Page 8...
Страница 22: ...1220C GB 19991004 18 Installation 1 1220C Cawomat 2000 IR RM 07 10 99 14 18 Page 18...
Страница 24: ...1220C GB 19991004 20 Getting started 2 1220C Cawomat 2000 IR RM 07 10 99 14 18 Page 20...
Страница 38: ...1220C GB 19991004 34 Cleaning 3 1220C Cawomat 2000 IR RM 07 10 99 14 18 Page 34...
Страница 50: ...1220C GB 19991004 46 Troubleshooting 4 1220C Cawomat 2000 IR RM 07 10 99 14 18 Page 46...
Страница 87: ...A Appendix Equipment information sheet 1220C Cawomat 2000 IR RM 07 10 99 14 20 Page 83...
Страница 88: ...1220C GB 19991004 84 Specifications A 1220C Cawomat 2000 IR RM 07 10 99 14 20 Page 84...
Страница 93: ...B Appendix Parts list and exploded views 1220C Cawomat 2000 IR RM 07 10 99 14 20 Page 89...
Страница 94: ...1220C GB 19991004 90 Parts list B 1220C Cawomat 2000 IR RM 07 10 99 14 20 Page 90...
Страница 135: ...C Appendix Index 1220C Cawomat 2000 IR RM 07 10 99 14 27 Page I 1...
Страница 136: ...1220C GB 19991004 I 2 Index C 1220C Cawomat 2000 IR RM 07 10 99 14 27 Page I 2...
Страница 141: ...1220C Cawomat 2000 IR RM 07 10 99 14 27 Page I 7...