6. 

SETTING CONTROL UNIT WORK PARAMETERS  

  

 

 

  

press

 

OK and 

 

until the

 

display

   

          

P2 

appears 

                                   

Press   

 

 

6.1 

BASIC MENU –DEFAULT PARAMETERS 

 

6.1.1 

 BOOST

  

 

 

 

Display: 

P2.10

 – Initial thrust force

 

                                 

 

 

 

Value expressed in

 %.  

       Default setting   = 15

%.    Press

 

 

  

6.1.2 

CO.MAX  

 

 

 

Display: 

P2.11

 – max torque 

 

 

 

Value expressed in

 % 

      Default setting  = 60

%.       Press

 

 

6.1.3 

SP. MAX AP 

 

 

 

Display: 

P2.12

 - Max. opening Speed 

 

 

 

Value expressed in Hz

 (

50:110)

   Default setting  = 50Hz       

Press

 

 

6.1.4 

SP. MAX CH   

 

 

Display: 

P2.13

 - Max. in closing speed 

 

 

 

Value expressed in Hz (50:110)   

Default setting = 50Hz      

Press

 

 

6.1.5 

SP. 

LOWAP 

   

Display: 

P2.14

 - Opening slow-down speed 

 

 

 

Value expressed in Hz

 

       Default setting = 20Hz      

Press

 

 

6.1.6 

SP. 

LOWCH 

   

Display: 

P2.15

 - Closing slow-down speed 

 

 

 Value expressed in Hz  

       

Default setting = 20Hz      

Press 

 

6.1.7 

RAMPA 

ACC. 

   

Display: 

P2.16

 – Acceleration ramp 

 

 

 

Value expressed in milliseconds  

Default setting = 350ms   

Press

 

 

6.1.8 

RAMPA 

DEC. 

   

Display: 

P2.17

 – Deceleration ramp 

 

 

 

Value expressed in milliseconds   

Default setting 

 = 1000ms 

Press

 

 

6.1.9 

Fotocel AP. 

  

 

 

Display: 

P2.18

 - Photocell behaviour in opening      

   Press 

 

 

 

Values:

 0

:

 

performs immediate opening.

 1

:

 

performs opening when photocell is free 

 

6.1.10 

INV.T 

AP. 

   

Display: 

P2.19

 – Inversion time of the motor in case obstacle check intervenes  

 

 

 

Value expressed in seconds         

Default setting = 0 s 

 

 

 Note:

 

= inversion until closing limit stop. 

 

    

 Press 

 

6.1.11 

INV.T 

CH. 

   

Display: 

P2.20

 - Inversion time of the motor in case obstacle check intervenes 

 

 

 

Value expressed in seconds       

Default setting   = 0 s 

 

 

 Note:

 

0

 = inversion until opening limit stop.

 

 

    

Press

 

6.1.12 

Pedestrian 

   

Display: 

P2.21

 - Pedestrian opening time  

 

 

 

Value expressed in seconds       

Default setting   = 3.0 s        

Press

 

 

6.1.13 

Colpo 

F    

Display: 

P2.22

 – Final thrust execution time. 

 

 

 Value expressed in seconds        

Default setting  = 0.5 s        

Press

 

 

6.1.14 

RUN 

TIME. 

   

Display: 

P2.23

 – Working time 

 

 

 

Value expressed in seconds       

Default setting   = 10.0 sec   

Press

 

 

6.1.15 

SLOWT. 

AP 

   

Display: 

P2.24

 – Slow-down time, before opening Limit stop. 

 

 

 

Value expressed in

 %         

        

Default setting   = 15% 

 

 

  

 

 

 

 

  

 

Press

 

6.1.16 

SLOWT. 

CH 

   

Display: 

P2.25

 - Slow-down time, before closing Limit stop. 

 

 

 

Value expressed in

 % 

     

Default setting   = 35% s 

 

 

 

 

 

 

 

.

  

 

Press

 

6.1.17 

Prelamp 

 

   

Display: 

P2.26

 - Flashing light pre-flash time 

Pagina 6 di 9                                  

 

 

 

Value expressed in seconds    

Default setting   = 2.0 s        

Press

 

Содержание EQ400I

Страница 1: ...rtita IVA 0050659 001 7 Reg Trib Torino N 654 62 C C I A A 333122 M T0024777 Sito www casit it E Mail info casit it INSTALLER TECHNICAL MANUAL GB ELECTRONIC CONTROL PANEL ONE THREE PHASE MOTOR EQ400I...

Страница 2: ...n on voltage and frequency Settable starting boost thrust Personalised partial opening pedestrian Stop time adjustable from 0 to 60 seconds with trimmer Personalised slow downs Personalised accelerati...

Страница 3: ...d DIPSW5 in OFF FC Ra Close 22 common at 24 Closing slow down limit stop NC or NA If not used leave open and set NA in P5 8 and SW5 in OFF Brake 27 NO 28 NC 29 C Relay switched Motor brake Rest Motor...

Страница 4: ...A Apre Start C Close P Pedestrian S Stop Values 1 Input closed connected and active 0 Input open not connected or deactivated Press Page P2 2 Limit stop RA Opening slow down RC Closing slow down FA Op...

Страница 5: ...ance connected photocell autotest failed etc This type of error prevents entering into programming See display P4 1 to show alarm produced 5 7 SETTINGS AND OPERATING LOGIC 5 7 1 Operating with automat...

Страница 6: ...play P2 18 Photocell behaviour in opening Press Values 0 performs immediate opening 1 performs opening when photocell is free 6 1 10 INV T AP Display P2 19 Inversion time of the motor in case obstacle...

Страница 7: ...the parameter from NO to NC and vice versa Display P5 1 Display P5 2 Display P5 3 Start Button Chiude Close Button Pedonale Pedestrian Default N Open Default N Open Button Default N Open Display P5 4...

Страница 8: ...EQ400I ENGLISH 7 DISPLAY FOR SHOWING AND PROGRAMMING THE CONTROL UNIT RESET display to start from the panel with the OK button pressed 0 Normal 1 Alarm Pagina 8 di 9 Rev 00 del 30 11 2009...

Страница 9: ...facturer and by current legislation All installation maintenance repairs and cleaning operations must be documented This documentation must be preserved by the user and made available to the personnel...

Отзывы: