EQ400I
ENGLISH
4. CONNECTION AND SETTING UP OF THE CONTROL UNIT
4.1 CONNECTION AND WIRING LAY-OUT DIAGRAM
4.2 WIRING AND CONNECTIONS (SEE FIGURE ON PAGE 17)
MAINS input:
(1)
Phase,
(2)
Neutral,
(3)
Earth –
Flashing light
220 VAC:
(4)-(5)
– fixed/flashing, according to setting
DIPSW6
.
Motor:
Earth:
(6)
, Motor earth:
(7)
, Motor phases (Delta connection):
(8)-(9)-(10)
Safety
Edge
in opening:
(11)
NC or resistance. – Safety
Edge
in closing:
(12)
NC or resistance. If not used jump to GND and
DIPSW7
in OFF.
Photocell: (14)
(common at +24). Photocell input NC or NO. If not used, leave open and set NA in
P5.9. (DIPSW3
in OFF)
FC Opening
:
(15)
(common at +24) Opening limit stop. NC or NO. If not used, leave open and set NA in
P5.5.
FC Ra Open
:
(21)
(common at +24) Opening slow-down limit stop. NC or NA. If not used, leave open and set NA in
P5.7
and
DIPSW5
in OFF
FC Ra Close
:
(22)
(common at +24) Closing slow-down limit stop. NC or NA. If not used, leave open and set NA in
P5.8
and
SW5
in OFF
Brake
:
(27)
NO,
(28)
NC,
(29)
C. Relay switched: Motor brake:
Rest
. Motor operation:
Activated
.
START
:
(30)
(common at +24). START Button. NO or NC. Set in
P5.1
STOP
:
(31)
(common at +24). STOP Button. NC or NO. Set in
P5.4
FC Closure
:
(33)
(common at +24). Closing limit stop NC or NO. If not used, leave open and set NA in
P5.6
Pedestrian
:
(36)
(common at +24). Pedestrian opening Button. NO or NC. Set in
P5.3
Close
:
(37)
(common at +24). Closing Button. NO or NC. Set in
P5.2
[
GND]: (13), (16), (24), (25), (35), (43) – [+24]: (17), (20), (23), (32), (34), 38), (41) – [Not used]: (19), (26), (39), (40), (42)
NOTE: in case of anomalous operations of photocells connect the negative of the receiver photocell to the earth
(metallic mass - gate or motor carter - NOT CONNECT IT TO THE CONTROL PANEL) with an additional thread
INTERPOSING A CAPACITOR IN SERIES 100noM 270V.
Attention!!
THE MOTOR MUST HAVE A DELTA CONNECTION
Pagina 3 di 9 Rev. 00 del 30/11/2009