SAFETY PRECAUTIONS 

 

These warnings are an essential, integral part of the product and must be given to the user. They provide important 
indications on the installation, use and maintenance and must be read carefully. This form must be preserved and 
passed on to subsequent users of the system. The incorrect installation or improper use of the product may be 
dangerous. 
 

 
INSTALLATION INSTRUCTIONS 

 

The installation must be performed by professionally skilled personnel and in compliance with current local, state, 

national and European legislation. 

 

Before beginning the installation, check the integrity of the product. 

 

The laying of cables, electrical connections and adjustments must be workmanlike performed. 

 

The packing materials (cardboard, plastic, polystyrene, etc.) are a potential hazard and should be disposed of correctly 

and not left within reach of children. 

 

Do not install the product in potentially explosive environments or environments disturbed by electromagnetic fields. The 

presence of inflammable gases or fumes is a grave danger to safety. 

 

Set up a safety device for overvoltage, a disconnecting and/or differential switch suitable for the product and conforming 

to current standards. 

 

The manufacturer declines any and all responsibility for product integrity, safety and operation in the event incompatible 

devices and/or components are installed. 

 

Solely original spare parts should be used for repairs and replacements. 

 

The installer must provide all the information relative to the operating, maintenance and use of the individual 

components and the complete system as specified in the MACHINE LEGISLATION (see regulations EN 12635, EN 
12453 and EN 12445). 

 
 

MAINTENANCE 

 

To ensure product efficiency, it is essential that professionally skilled personnel carry out maintenance within the times 

established by the installer, the manufacturer and by current legislation. 

 

All installation, maintenance, repairs and cleaning operations must be documented. This documentation must be 

preserved by the user, and made available to the personnel responsible for the control. 

 
 

WARNINGS FOR THE USER 

 

Read the instructions and enclosed documentation carefully. 

 

The product must be used for the express purpose for which it was designed. Any other use is considered improper and 

therefore hazardous. In addition, the information given in this document and in the enclosed documentation may be 
subject to modifications without prior notice. It is given as an indication only for product application. 

Casit

 declines any 

responsibility for the above.  

 

Keep products, devices, documentation and anything else provided out of reach of children.  

 

In the event of maintenance, cleaning, breakdown or faulty operation of the product, cut off the power and do not 

attempt to operate on the product except when indicated. Contact professional personnel, competent and suitable for the 
task. Failure to adhere to the above indications may be dangerous. 

 
 
WARRANTY LIMITS 

The warrantee is valid for 12 months from the date indicated in the sales document and its validity is limited to the original 
purchaser. It does not cover the following eventualities: negligence, incorrect or improper use of the product, use of 
accessories not conforming to the manufacturer's specifications, tampering by the customer or third parties, natural 
causes (lightning, floods, fire, etc.), riots, vandalism, modifications to the environmental conditions of the installation site. 
Nor does the warranty cover parts subject to wear (batteries, oil etc.). Products returned to Casit  for repair shall only be 
accepted carriage paid. Casit shall return the repaired product to the sender carriage forward. Otherwise the goods will be 
refused on receipt. The purchase of the product implies the full acceptance of all the general terms of sale. Any dispute 
shall be submitted for judgement to the Court of Torino. 

 
 

 
 

 

Pagina 9 di 9                                                                                                                                                              Rev. 00 del 30/11/2009

 

 

Содержание EQ400I

Страница 1: ...rtita IVA 0050659 001 7 Reg Trib Torino N 654 62 C C I A A 333122 M T0024777 Sito www casit it E Mail info casit it INSTALLER TECHNICAL MANUAL GB ELECTRONIC CONTROL PANEL ONE THREE PHASE MOTOR EQ400I...

Страница 2: ...n on voltage and frequency Settable starting boost thrust Personalised partial opening pedestrian Stop time adjustable from 0 to 60 seconds with trimmer Personalised slow downs Personalised accelerati...

Страница 3: ...d DIPSW5 in OFF FC Ra Close 22 common at 24 Closing slow down limit stop NC or NA If not used leave open and set NA in P5 8 and SW5 in OFF Brake 27 NO 28 NC 29 C Relay switched Motor brake Rest Motor...

Страница 4: ...A Apre Start C Close P Pedestrian S Stop Values 1 Input closed connected and active 0 Input open not connected or deactivated Press Page P2 2 Limit stop RA Opening slow down RC Closing slow down FA Op...

Страница 5: ...ance connected photocell autotest failed etc This type of error prevents entering into programming See display P4 1 to show alarm produced 5 7 SETTINGS AND OPERATING LOGIC 5 7 1 Operating with automat...

Страница 6: ...play P2 18 Photocell behaviour in opening Press Values 0 performs immediate opening 1 performs opening when photocell is free 6 1 10 INV T AP Display P2 19 Inversion time of the motor in case obstacle...

Страница 7: ...the parameter from NO to NC and vice versa Display P5 1 Display P5 2 Display P5 3 Start Button Chiude Close Button Pedonale Pedestrian Default N Open Default N Open Button Default N Open Display P5 4...

Страница 8: ...EQ400I ENGLISH 7 DISPLAY FOR SHOWING AND PROGRAMMING THE CONTROL UNIT RESET display to start from the panel with the OK button pressed 0 Normal 1 Alarm Pagina 8 di 9 Rev 00 del 30 11 2009...

Страница 9: ...facturer and by current legislation All installation maintenance repairs and cleaning operations must be documented This documentation must be preserved by the user and made available to the personnel...

Отзывы: