background image

IOM-HP-S-DIFF

7

SECTION VIII

Possible Cause

Remedy

A.

Plugged body spacer vent hole.

A.

Clean vent opening.

B.

Plugged piston balance port.

B.

Re move trim and clean balance port.

C.

Fluid too viscous.

C.

Heat fluid.  Contact factory.

5 Sluggish 

operation.

6.  Excessive seat leakage.

Possible Cause

Remedy

A.

Foreign matter on seating surface, erosion of seating surface.

A.

In spect and replace damaged parts.

B.

Quad ring/backup ring damaged, scratched body cap.

B.

Inspect and replace damaged parts. 

C.

Cylinder gasket damaged.

C.

Inspect and replace damaged part. 

NEW REPLACEMENT UNIT:

Contact your local Cashco, Inc., Sales Rep re sen-
 ta tive with the Serial Number and Product code.  
With this information they can provide a quotation 
for a new unit including a complete description, 
price and availability.

7

VIII. ORDERING 

INFORMATION

 

 

NEW REPLACEMENT UNIT vs PARTS  "KIT" FOR FIELD REPAIR 

To obtain a quotation or place an order, please retrieve the Serial Number and Product Code that was stamped 
on the metal name plate and attached to the unit.  This information can also be found on the Bill of Material 
("BOM"), a parts list that was provided when unit was originally shipped. (Serial Number typically 6 digits).  
Product Code typical format as follows:  (last digit is alpha character that reflects revision level for the product).

PARTS "KIT" for FIELD REPAIR:

Contact your local Cashco, Inc., Sales Rep re sen-
 ta tive with the Serial Number and Product code.  
Identify the parts and the quantity required to repair 
the unit from the "BOM" sheet that was provided 
when unit was originally shipped. 

NOTE:

 

  Those part numbers that have a quantity indicated 

under  "Spare Parts" in column "A” reflect minimum 
parts required for inspection and rebuild, - "Soft 
Goods Kit".  Those in column “B” include minimum 
trim replacement parts needed plus those "Soft 
Goods" parts from column "A".

If the "BOM" is not available, refer to the cross-
sectional drawings included in this manual for part 
identification and selection.

A Local Sales Representative will provide quotation 
for appropriate Kit Number, Price and Availability

.

          CAUTION

Do not attempt to alter the original construction 
of any unit without assistance and approval from 
the factory.  All purposed changes will require a 
new name plate with appropriate ratings and new 
product code to accommodate the recommended 
part(s) changes.

The contents of this publication are presented for informational purposes only, and while every effort has been made to ensure their accuracy, they are not to be 

construed as warranties or guarantees, express or implied, regarding the products or services described herein or their use or applicability.  We reserve the right to 

modify or improve the designs or specifications of such product at any time without notice.

Cashco, Inc. does not assume responsibility for the selection, use or maintenance of any product.  Responsibility for proper selection, use and maintenance of any 

Cashco, Inc. product remains solely with the purchaser.

Содержание HP-1+6+S

Страница 1: ...g plus an additional loading PLOAD pressure connected to the spring chamber The loading PLOAD pressure plus the range spring 14 setting PSET equals the outlet P2 pressure of the regulator The range sp...

Страница 2: ...ifferential setting use one of the two following methods NOTE Both methods require a flowing condition a Loosen the closing cap 28 by turning CCW as viewed from above 3 to 4 complete revolutions Loose...

Страница 3: ...CCW rotation used to relieve range spring 14 tension will come to a stop At the stopping point do not apply any torque to adjusting screw 6 or damage may occur and render the unit inoperable See Figur...

Страница 4: ...e spring chamber 2 centered on body 1 and prevent parts from moving during re assembly Using the match marks made in Step 3 as a guide replace spring chamber 2 onto body spacer 24 Thread on lower nuts...

Страница 5: ...akage not to exceed 15 bubbles per minute Do not allow excessive buildup if seat leakage exists crack open No 2 shut off valve to prevent buildup If seat leakage is excessive proceed with the followin...

Страница 6: ...elow load pressure PLOAD D1 D2 Review Proportional Band droop expected Contact factory E Restricted diaphragm movement E Ensure no moisture in spring chamber at temperatures below freeze point 2 Downs...

Страница 7: ...sen tative with the Serial Number and Product code Identifythepartsandthequantityrequiredtorepair the unit from the BOM sheet that was provided when unit was originally shipped NOTE Those part numbers...

Страница 8: ...Parts 15 Piston w TFE Seat 16 Cylinder 17 Piston Spring 18 Cylinder Gasket 23 Cap Screw 24 Body Spacer 25 Body Cap O Ring 26 Quad Ring 27 Backup Ring 28 Closing Cap 30 O ring 2 req d 31 Quad Ring 32...

Страница 9: ...ive The details of the assessment in terms of the individual Essential Health and Safety Requirements are listed in Table 1 Table 2 lists all of the models and options that were evaluated and along wi...

Страница 10: ...d follow the same requirements for the piping system Also see item 30 in Table 1 2 The system designer and users must take precautions to prevent rapid system pressurization which may raise surface te...

Отзывы: