7.4 Learning remote-control codes:
- Control panel can memory more than 50 pcs remote controls.
- Code learning: Press board «LEARN» button. LED indicator
lights on.
- Press remote control first button. LED indicator flashes twice
= code learning succeed.
If no remote-control signals received within 2.6s, the receiver
will automatic quit learning functions.
- Code clearing: Press and hold the button 6 seconds. LED
indicator flashes twice = all the code that has been memorized
in control board will be cleared.
Learning button
Close sensitivity
adjusting
5&6:
Auto-close setting time when pedestrian mode is activated.
When remote control triggers the pedestrian mode (remote control button 2 or 4), the gate will stop
after opening for 6s. If auto-close function activated, the gate will auto-close after gate open to 6s.
Auto-close time setting as follows:
• No° 5 &6, OFF-OFF: Auto close function disabled (Factory setting)
• No° 5 &6, ON-OFF: 5S
• No° 5 &6, ON-ON:10S
• No° 5 &6, OFF-ON: 30S
Note:
When the motor is running, the motor will stop immediately if triggers pedestrian mode.
After triggering the pedestrian mode to open the gate for 6s, no matter it enters the countdown to close
the gate or stop status. If trigger again, the gate will close the gate immediately.
7: Condominium mode setting
.
OFF: Condominium mode disabled (factory setting).
ON: Condominium mode activated.
When the gate is opening it triggers remote control and the start interface are invalid until the door is
opened.
When the gate is closing it triggers remote control and the start interface. The gate will stop to close
and auto-open until the opening limit is reached. The remote control and the start interface are invalid
when the gate is opening.
8: Remote control buttons mode.
OFF: Single button control circularly.
First button controls gate open, stop, close, second button use for pedestrian mode.
ON: Three buttons control.
First button controls gate open, second button controls gate stop, third button controls gate close ,
fourth button used for pedestrian mode
Note: Please choose the remote-control’s mode firstly before remote control code clearning to control
board
7.4
Содержание TANKER C600
Страница 5: ...EN 5 Serial Number...
Страница 10: ...EN 10 Control board setting Yellow Blue Red...
Страница 13: ...EN 13 Connection of the flashing light Connection of infra red photocells...
Страница 24: ...FR 24 Num ro de s rie...
Страница 29: ...FR 29 Param trage de la carte de contr le Jaune Bleu Rouge...
Страница 32: ...FR 32 Connexion des lampes flash Connexion des cellules photo lectriques...
Страница 43: ...DE 43 Seriennummer...
Страница 48: ...DE 48 Einrichten der Regelkarte Gelb Blau Rot...
Страница 51: ...DE 51 Anschluss f r Blitzlampe Photoelektrische Zellenverbindung...
Страница 62: ...ES 62 N mero de serie...
Страница 67: ...ES 67 Configurando la carta de control Amarillo Azul Rojo...
Страница 70: ...ES 70 Conexi n de la l mpara de flash Conexi n de la c lula fotoel ctrica...
Страница 81: ...PT 81 N mero de s rie...
Страница 86: ...PT 86 Elabora o do gr fico de controlo Amarelo Azul Vermelho...
Страница 89: ...PT 89 Liga o da l mpada flash Liga o de c lula fotoel ctrica...
Страница 100: ...IT 100 Num ro de s rie...
Страница 105: ...IT 105 Impostazione della tabella di controllo Giallo Blu Rosso...
Страница 108: ...IT 108 Collegamento lampada flash Collegamento della cellula fotoelettrica...
Страница 119: ...NL 119 Serienummer...
Страница 124: ...NL 124 Opzetten van de regelkaart Geel Blauw Rood...
Страница 127: ...NL 127 Aansluiting voor flitslampen Foto elektrische celverbinding...
Страница 138: ...PL 138 Numer seryjny...
Страница 143: ...PL 143 Ustawianie schematu kontrolnego ty Niebieski Czerwony...
Страница 146: ...PL 146 Pod czenie lampy b yskowej Po czenie z kom rk fotoelektryczn...