71
▣
Output Signal Condition Byte
Bit 7
Bit 6
Bit 5
Bit 4
Bit 3
Bit 2
Bit 1
Bit 0
Stable
Finish
Low limit
High limit
Final
Optional
preliminary
Preliminary
Zero
▣
Error message output
Byte 1
Byte 2
Byte 3
Byte 4
Byte 5
Byte 6
Byte 7
Byte 8
Byte 9
E
R
R
Error code
CR
LF
* Each error message is outputted by 9 byte through COM(Serial).
8-3-2. 10bytes of CAS
(1) Data Bit : 8, Stop Bit : 1, Parity Bit : None
(2) Code : ASCII
(3) Transmit Data Format (10 BYTE)
Data (8 Bytes)
CR
LF
8-3-3. 18bytes of AND
(1) Data Bit : 7, Stop Bit : 1, Parity Bit : Odd/Even
(2) Code : ASCII
(3) Transmit Data Format (18 BYTE)
,
,
Data (8Bytes)
CR
LF
└──┘
└──┘
└──┘
US(Unstable) GS(GROSS weight) Unit (kg/t)
ST(Stable) NT(NET weight)
OL(Overload)