21
CAL 1
(CAL 1 Start automatically)
Function : Maximum Capacity(range: 1 ~ 99,999)
KEY
VFD SCREEN
DESCRIPTION
C = 10
Maximum capacity is 10
C = 100
Maximum capacity is 100
C = 1000
Maximum capacity is 1000
▲
,
▼
: increase or
decrease of no.
, : Shift of digit
▶◀
”* " : Cancel and
move to CAL-1
Enter : Store and move
Into next menu
C = 10000
Maximum capacity is 10000
Ref 1. The maximum value means the maximum weight that a scale can measure.
CAL 2
Function : Setting Minimum division and Dot position
Setting value range : 0.001 ~ 50
USED KEY
VFD SCREEN
DESCRIPTION
div = 0.001
Minimum division : 0.001 kg
div = 0.01
Minimum division : 0.01kg
div = 0.1
Minimum division : 0.1 kg
▲
,
▼
: increase or decrease of
no.
▶
,
◀
: Shift of digit
”* " : Cancel and
move to CAL-1
Enter : Store and move
into next menu
div = 1
Minimum division : 1kg
Ref 1. Minimum division means mininum change(one division value) of unit of weighing change.
Ref 2. External resolution is the value dividing maximum weight into minimum devision, and its setting range
should be less than 1/10,000.
Ref 3. Dot position is decided by dot position of minimum devision set in CAL2 mode.
Содержание NT-580A
Страница 1: ...2 ...
Страница 12: ...13 2 Measure of Appearance 2 1 Measure of Appearance ...
Страница 24: ...25 4 4 Sealing Method Sealing Method of front cal switch ...
Страница 53: ...54 External Control I O Circuit ...
Страница 58: ...59 Normal Batching Diagram Loss in Weight Batching Diagram ...
Страница 59: ...60 UserProgramControlMode NormalBatching ...
Страница 61: ...62 UserProgramControlMode Loss in WeightBatching ...
Страница 63: ...64 AutomaticProgramControlMode NormalBatching ...
Страница 65: ...66 AutomaticProgramControlMode Loss in Weight Batching ...
Страница 85: ...86 MEMO ...
Страница 86: ...87 ...
Страница 87: ...88 ...