19
3. Installation & Connection
3-1. Loadcell Connection
Connect the load cell connector to the load cell port which is in the backside of the
indicator.
* Connection method
Note . In case of the 4 wires load cell, connect EX+ with SEN+, and connect EX- with SEN-.
Note . Fix a loadcell wire as above picture by using cable tie.
PIN
6 Wires
4 Wires
1(Red)
EXC+
5 (Brown) SEN+
EXC+
(Connect to
1,5 pin)
2 (White)
EXC-
6 (Black)
SEN-
EXC+
(Connect to
1,5 pin)
3 (Green)
SIG+ SIG+
4 (Blue)
SIG- SIG-
7 (Black) SHIELD