5-3-4. Batching Operation Function
F50
Function
Measurement Mode
VFD Display
DESCRIPTION
F50 0
Do not Use
F50 1
Normal batching
F50 2
Customer
Programmed
Control Mode
Loss-in-weight
batching
F50 3
Normal batching
Set Value
(0 ~ 4)
F50 4
Built-in automatic
program Mode
Loss-in-weight
batching
Plea
※
se refer to each operation on Page 70.
F53
Function
Timer - Start Delay Time
VFD Display
DESCRIPTION
F53 00
No delay time
F53 10
1.0 sec
Set Value
(00 ~ 99)
F53 99
9.9 sec
Ref 1.
. It is used only in the built-in automatic program Mode
.
F54
Function
Timer - Finish Signal Start Delay Time
VFD Display
DESCRIPTION
F54 00
No delay time
F54 10
1.0 sec
Set Value
(00 ~ 99)
F54 99
9.9 sec
Ref 1.
It is used to set the delay time of the finish signal after the batching operation
.
.