34
Serial Interface of COM1 Function
F28
Function
Set Baud Rate of COM1
VFD Display
DESCRIPTION
F28 0
600 bps
F28 1
1200 bps
F28 2
2400 bps
F28 3
4800 bps
F28 4
9600 bps
F28 5
19200 bps
F28 6
38400 bps
F28 7
57600 bps
Set Value
(0 ~ 8)
F28 8
115200 bps
F29
Function
Usage of COM1
VFD Display
DESCRIPTION
F29 0
Connection with printer
Set Value
(0 ~ 1)
F29 1
Connection with sub-display or computer
* F29 =0 and F33 = 0 then “Err-Set” displayed. and the print is disconnected.
F30
Function
Output Format of COM1
VFD Display
DESCRIPTION
F30 0
22Bytes – CAS Format
F30 1
10Bytes – CAS Format
Set Value
(0 ~ 2)
F30 2
18Bytes – AND Format
F31
Function
Output Mode of COM1
VFD Display
DESCRIPTION
F31 0
No data transmission
F31 1
Transmit data in a state of stable & unstable (Stream Mode)
F31 2
Transmit data only in stable condition
(Transmit 1 time after load in stable condition)
F31 3
Transmit data if you input Device ID
* Device ID (F31) Input 1Byte (hex code)
(Data Request _Device ID : 1= 0x01, 10 = 0x0A)
Set Value
(0 ~ 4)
F31 4
Transmit data only in command Mode
* If it is used as the print Mode, set F31 = 1.
Содержание NT-580A
Страница 1: ...2 ...
Страница 12: ...13 2 Measure of Appearance 2 1 Measure of Appearance ...
Страница 24: ...25 4 4 Sealing Method Sealing Method of front cal switch ...
Страница 53: ...54 External Control I O Circuit ...
Страница 58: ...59 Normal Batching Diagram Loss in Weight Batching Diagram ...
Страница 59: ...60 UserProgramControlMode NormalBatching ...
Страница 61: ...62 UserProgramControlMode Loss in WeightBatching ...
Страница 63: ...64 AutomaticProgramControlMode NormalBatching ...
Страница 65: ...66 AutomaticProgramControlMode Loss in Weight Batching ...
Страница 85: ...86 MEMO ...
Страница 86: ...87 ...
Страница 87: ...88 ...