16
Outdoor Air Temperature Sensor (OAT)
An optional outdoor air temperature (OAT) sensor is provided in
the literature package. Install the sensor outdoors, typically on the
north side of the residence away from direct sunlight. Sensor
package includes an adhesive holder for the sensor. See Fig 20 for
wiring the sensor to the OAT plug on the fan coil or furnace unit
control board. Do not connect to the optional remote sensor
terminals (S1, S2) on the UI.
Humidity control uses the OAT to adjust humidity target when the
OAT drops into the cold range to prevent forming of condensation
on windows.
It also allows the UI to display outdoor air
temperature.
A150195
Fig. 20 -- OAT Sensor Connection
Compressor Start Accessories
In the event of the rare occurrence of compressor starting issues
such as dimming of the residential lights. Verify and correct
voltage issues and add hard start components. Table 10 lists Hard
Start components that are recommended in areas of poor power
conditions.
Table 10 – Recommended Hard Start Kits
Unit Size
Compressor
Hard Start Kit
Start Cap
Start MFD
Start Cap Volts
Start Relay
GZ024
ZPS20K5E---PFV
KSAHS2501AAA
HC95DE088
88---108
330
HN61HB540
GZ036
ZPS30K5E---PFV
KSAHS2501AAA
HC95DE088
88---108
330
HN61HB540
GZ048
ZPS40K5E---PFV
KSAHS2801AAA
HC95DE088
88---108
330
HN61HB553
GZ060
ZPS51K5E---PFV
KSAHS2801AAA
HC95DE088
88---108
330
HN61HB553
GZ072
ZPS60K5E---PFV
N/A
014---0053---38
43
330
HN61HB553