42
6.3.3.
Furnace
First touch
SETUP
, then touch
FURNACE
to set up the parameters for the furnace
unit.
A14225A
6.3.3.1.
Furnace Airflow
Selects the airflow of the furnace when heating.
EFFICIENCY
is the airflow used
to meet specified ratings,
COMFORT
is a decreased airflow used to increase the
output air temperature and provide increased comfort.
For the Low heat rise option, set to ON if the system contains a bypass humidifier.
The ON setting will increase the furnace low heat airflow.
After the selections are made, touch
SAVE
.
S
Furnace Air Flow:
Comfort or Efficiency
d
Default = Comfort
S
Low Heat Rise:
On or Off
d
Default = Off