15
S
Secure mounting plastic to wall using two screws and anchors provided.
S
Adjust length and routing of each wire to reach each wire entry on the
connector backplate. Strip 1/4--in (6.4 mm) of insulation from each wire.
S
Match and connect thermostat wires to proper terminals on control backplate.
d
See wiring diagrams in Section 8.0.
S
Push any excess wire into the wall. Seal hole in wall to prevent any air leaks.
Air leaking from behind the wall can affect measured temperature and
humidity, and can affect operation.
S
Attach Infinity System Control to the mounting plastic by lining up the plastic
guides on the back of the control with the opening on the mounting plastic and
push on.
S
Perform installation of all other system equipment (i.e. dampers, humidifier,
ventilator, UV lights, etc.). See the equipment and device installation
instructions for details.
S
Turn on power to equipment.
Содержание A180218C
Страница 2: ...US Patents Carrierr U S Pat No 7 243 004 Carrierr U S Pat No 7 775 452 pointSETt U S Pat No 7 415 102...
Страница 64: ...54 A160188C...
Страница 112: ...102 A160170 NIM Chart...
Страница 113: ...103 A160171 Wiring Diagram Single Stage Non Communicating Heat Pump NIM...
Страница 114: ...104 A160172 Wiring Diagram Two Stage Non Communicating Heat Pump NIM...
Страница 115: ...105 R G FE Fan Coil or Variable Speed Furnace A07114 G Input Wiring for Blower Operation...
Страница 116: ...106 R G FE Fan Coil or Variable Speed Furnace A07115 G Input Wiring for System Shutdown...
Страница 119: ...109 NOTES...