RVDF Advanced User Manual
6
Specifications are subject to change without notice. Pictures are just an example. For special features and/or customization, please ask to our sales network. 23/03/2011
Warning
• Do not attempt to install or remove input or output connectors of inverter when the power
supply is turned on. Otherwise, the inverter may be damaged due to the surge peak
caused by the insertion or removal of power.
• When momentary power loss is longer than 2 seconds (the large of horse power, the
longer of time), the inverter does not have enough storage power to control the circuit;
Therefore, when power is regenerated, the operation of the inverter is based on the setup
of F_10 and the condition of external switch, this is considered to be restart in the
following paragraphs.
? When the momentary power loss is short, the inverter still has enough storage power to
control the circuit; therefore, when power is regenerated, the inverter will automatically
start operation again depends on the setup of F_23.
• When restart the inverter, the operation of the inverter is based on the setup of F_10 and
the condition of external switch (FWD/REV button). Attention: the restart operation is
irrelevant with F_23/F_24.
(1) When F_10=0, the inverter will not start after restart.
(2) When F_10=1 and the external switch (FWD/REV button) is OFF, the inverter will not
start after restart.
(3) When F_10=1 and the external switch (FWD/REV button) is ON, the inverter will start
automatically after restart. Attention: Base on safety reason, please turn off the external
switch (FWD/REV button) after power loss to avoid possible damage to the machine and
the human body after sudden regeneration of power.
1.1.2 When power is applied
1.1.3 Under Operation
Caution
• Do not touch the heat-sink base during operation.
• The inverter can be easily operated from a low-speed to high-speed range. Please
reconfirm the operating range of motor and the machinery you are controlling.
• Do not examining the signals on the PCB of the inverter when it is under operation.
• All inverters are properly adjusted and set before delivery.
Warning
Do not use a separate device to switch ON or OFF motor during operation. Otherwise, the
inverter may experience an over-current breakdown.
Warning
• Do not remove the front cover of the inverter when the power is ON to avoid personnel
injury caused by electrical shock.
• When the automatic restart function is enabled, the motor and machinery will be restarted
automatically.