Specifications are subject to change without notice. Pictures are just an example. For special features and/or customization, please ask to our sales network. 23/03/2011
27
F_04: Motor rotation direction setting = 0: Forward
1: Reverse
Although there is no Forward / Reverse push button on the digital control panel, it is possible to
adjust forward / reverse function by changing the F_04 setting.
NOTE:
When F_22 =1: Reverse is disabled, the F_04 cannot be set to 1.
The keypad indication would display “LOC”.
F_05: V/F pattern setting = 1 ~ 6
Selecting F_05 = 1-6 to select one of the six preset V/F patterns. (Refer to the following tables)
Specification
50 Hz System
Application
General Application
High starting torque
Decreasing torque
F_5
1
2
3
V/F pattern
Specification
60Hz System
Application
General Application
High starting torque
Decreasing torque
F_5
4
5
6
V/F pattern
V (%)
V (%)
V (%)
V (%)
V (%)
V (%)
100
B
C
100
B
C
100
B
C
100
B
C
100
B
C
100
B
C
1 2.5 50 120
1 25 50 120
1 2.5 50 120
1 3.0 60 120
1 3.0 60 120
1 30 60 120
Hz
Hz
Hz
Hz
Hz
Hz
F_5
B
C
1/4
10%
8%
2/5
15%
10.5%
3/6
25%
7.7%
RVDF Advanced User Manual