background image

 

 

_________________________________________________________________________________________________________________________ 
Card Access Sensor Bridge 

 

       

      Page 10 of 12 

Quick Start & Installation Guide 

 

 

Card Access, Inc.

 

 

Smoke Detector Driver Details 

 

Supported Devices:  

o

  GE Supervised Wireless Smoke Detector 

Card Access Model Number: GSD10A 

GE Model Number: TX-6010-01-1 

 

NOTE:

 This driver MUST be used in conjunction with the Card 

Access Sensor Bridge hardware and DriverWorks driver. GE 
Wireless Sensors do NOT need to be associated in any way with a 
specific Sensor Bridge in Composer. 

 

 

Properties Page Help

o

 

Sensor TxID:

 Enter the TxID printed on the Sensor Label. 

The TxID is a 6 or 7-digit alphanumeric address. 

o

 

Sensor Name:

 An optional descriptive name may be entered 

here. This name is displayed on the property page of the 
Bridge when data for this sensor is received. 

o

 

 Alarm Contact State: 

shows the current state of the alarm as 

"Alarm" (meaning smoke is detected) or "No Alarm" 
(meaning no smoke has been detected).

 

o

 

Sensor Status:

 shows whether the sensor as "Online" or 

"Offline." This status is affected by the connection state of 
the Sensor Bridge(s). 

o

 

Last Sensor Event

: shows the date and time of the last event 

received, as well as the contact status and low-battery 
status. 

o

 

Last Signal Level:

 shows the approximate signal level of the 

last received event. Use this level to aid in proper positioning 
of sensors.  

o

 

Supervisory Timeout

: sets the number of supervisory periods which must be missed before the “Supervisory 

Lost” event is triggered. Supervisory periods for these sensors are every 64 minutes. 

o

 

Supervisory State:

 shows current state of the supervisory signal monitor. 

o

 

Statistics:

 shows the number of events and RX success of the sensor. 

 

 

Actions Page Help: 

 

Identify Sensor:

 Click this button to allow the driver to automatically 'learn' the TxID of the sensor. After clicking 

the button, activate the 'Tamper' signal on the smoke detector by separating the unit from the mounting base. 
When the sensor has been successfully identified, the TxID will appear in the Sensor TxID field of the Driver 
Properties page.

 

 

 

Cancel Identify

: Click this button to abort the sensor identify process. Note that clicking this button is not 

necessary if you have successfully identified a sensor.

 

 

 

 

Содержание ZGB10A

Страница 1: ...______________________________________________________________________________ Card Access Sensor Bridge Page 1 of 12 Quick Start Installation Guide Card Access Inc Sensor Bridge Model Numbers ZGB10A ZGB10A ZP Quick Start and Installation Guide ...

Страница 2: ...______________________________________________________________________________________________________________________ Card Access Sensor Bridge Page 2 of 12 Quick Start Installation Guide Card Access Inc ...

Страница 3: ...device gives the homeowner the ability to utilize the wide range of GE sensors available as accessories to the Control4 system The device consists of a self contained wall mountable bridge in a plastic enclosure It is powered by a 12V DC adapter Specifications ZGB10A Specifications Dimensions 4 6 x 14 4 x 1 5 117mm x 366mm x 38mm Weight 0 5 Lbs 0 23Kg Maximum Ambient Operational Temperature 140 F ...

Страница 4: ... circuit board may be hinged out of the bridge base plastics to gain better access to the mounting holes by pulling downward on the retaining latch with a finger 4 Drill holes and insert the appropriate anchors 5 Use the wire access hole to route the wires from the DC power supply included into the bridge base 6 Secure the bridge base to the wall with the pan head screws provided 7 To assemble the...

Страница 5: ...tton at the top of the screen 3 When prompted to identify the unit press the ID button on the Bridge by using a paper clip inserted through the small hole located on the face of the Bridge Press the button four times in succession The BUS LED on the Sensor Bridge will begin blinking as it attempts to join the ZigBee mesh and identify into the Control4 project 4 When the Sensor Bridge has successfu...

Страница 6: ...he wireless sensor Then click the Set button 4 Test the sensor by activating deactivating the sensor s input You will see the sensor status populate on the properties page as well as the wireless signal level of the sensor to bridge connection 5 Select the generic proxy of your choice and at it to your project Go to the Connections tab and under Control AV bind the output for the sensor to this pr...

Страница 7: ...rivers provide a good deal of diagnostic information to assist in deployment of Sensor Bridges as well as placement and testing of wireless sensors The information below is also included in the Documentation tab of each driver ZGB10A Driver Details Supported Devices o First Card Access Sensor Bridge in a project Model Number ZGB10A Properties Page Help o Bridge Status Displayed as Online or Offlin...

Страница 8: ...us and low battery status o Last Signal Level shows the approximate signal level of the last received event Use this level to aid in proper positioning of sensors o Supervisory Timeout sets the number of supervisory periods which must be missed before the Supervisory Lost event is triggered Supervisory periods for these sensors are every 64 minutes o Supervisory State shows current state of the su...

Страница 9: ...or Status shows whether the sensor as Online or Offline This status is affected by the connection state of the Sensor Bridge s o Last Sensor Event shows the date and time of the last event received as well as the contact status and low battery status o Last Signal Level shows the approximate signal level of the last received event Use this level to aid in proper positioning of sensors o Supervisor...

Страница 10: ...her the sensor as Online or Offline This status is affected by the connection state of the Sensor Bridge s o Last Sensor Event shows the date and time of the last event received as well as the contact status and low battery status o Last Signal Level shows the approximate signal level of the last received event Use this level to aid in proper positioning of sensors o Supervisory Timeout sets the n...

Страница 11: ... ZGB10A to which this declaration relates are in conformity with the following standards and or other normative documents EN60950 EN55022 EN55024 We hereby declare that the above named product is in conformity with the essential requirements and other relevant provisions of Directive 1999 5 EC The conformity assessment procedure referred to in Article 10 3 and detailed in Annex II of Directive 199...

Страница 12: ...cannot guarantee the accuracy of any information presented after the date of this document s publication COPYRIGHT 2009 Card Access Inc All rights reserved Any previously copyrighted contents contained herein remain the property of the respective creators Card Access The Wire Stops Here and Do More Control More Make More are trademarks of Card Access Inc Control4 is a registered trademark and 4Sig...