Inputs
Door Contact (2 per panel) ……………………………Requires normally closed contact
(On/Off door switch)
Exit Button (2 per panel) ………………..………………Requires
normally open contact
(Momentary push button switch)
(M
Communications and Reader Cable
RS-485 Cable……………………………………22 AWG, stranded/shielded, twisted pair
.....................................................
609 m [2000 ft] max total length
........................................................................
Belden 88761 or equivalent
NOTE
:
Up to 16 controllers may be connected on an RS-485 bus.
Wiegand Readers ........................................ 6 conductor (twisted pair not required)
..............................................................................
22 AWG, overall shield
.........................................................................
152 m [500
ft] max. length
NOTE
:
Consult reader specifications as 12-gauge wire may be required for power.
Dimensions & Weight
H1000 Controller……………….……………………………………………………..7” (L) x 7” (W)
[18 cm (L) x 18 cm (W)]
H1000 Enclosure ……………………………………………..13” (W) x 19” (H) x 3 5/8” (D)
[33 cm (W) x 48 cm (H] x 9.2 cm (D)]
Controller Weight .............................................................................. 300 g [10.7 oz]
Enclosure Weight ............................................................................... 4.3 kg [9.6 lbs]
Note:
Specifications subject to change without notice.
NOTE: Tech Support will only be provided where product installation guidelines