CHAPTER 7 UPGRADING
7-8
1.3 Downloading the System Software, RUI, and Language Module
1.3.1 Making Connections
The discussions that follow are based on the use of a parallel cable:
•
Check to make sure that the Processing/Data lamp is OFF.
1) Turn off the machine’s main power switch, and disconnect the power plug and the
network cable.
2) Using a parallel cable, connect the PC to the parallel connector on the left side of the
controller.
•
At this time, the PC must remain OFF.
•
Connect the 25-pin connector of the cable to the PC and the 36-pin connector to the ma-
chine.
3) Turn on the power switch of the PC, and start up the Service Support Tool.
4) Connect the machine’s power plug to the power outlet, and turn on the main power
switch.
1.3.2 Downloading
1) Under ‘Downloading/Uploading’, select ‘To Next’.
F07-103-01