CHAPTER 6 SELF DIAGNOSIS
6-21
E601
0000
When an image is transferred between the main controller PCB and the
HDD, the main controller PCB detects a fault in control information.
0001
When an image is transferred between the main controller PCB and the DC
controller PCB, the DC controller PCB detects a fault in the control infor-
mation.
Main cause
The wiring is faulty (short circuit, open circuit). The HDD is faulty. The DC
controller PCB is faulty. The main controller PCB is faulty
Action
a. E601-0000
1. Wiring
Are the connection and the cable between the connector J1017 on the main
controller PCB and the connector J1551 on the HDD normal?
YES: End.
NO:
Correct the connection/cable.
2. HDD, Main controller PCB
Try replacing the HDD, and download the system software. Is the problem
corrected?
YES: End.
NO:
Replace the main controller PCB.
b. E601-0001
1. Wiring
Are the connection and cable between the connector J122 on the DC con-
troller PCB and the connector J1015 on the main controller PCB normal?
NO:
Correct the connection/cable.
2. DC controller PCB, Main controller PCB
Try replacing the DC controller PCB. Is the problem corrected?
YES: End.
NO:
Replace the main controller PCB.
Содержание iR2200 Series
Страница 18: ......
Страница 50: ...CHAPTER 4 TROUBLESHOOTING IMAGE FAULTS MALFUNCTIONS 4 4 Blank Page...
Страница 51: ......
Страница 100: ...CHAPTER 4 TROUBLESHOOTING IMAGE FAULTS MALFUNCTIONS 4 54 6 2 4 Fans F04 602 03 FM4 FM5 FM1 FM2 FM3...
Страница 110: ...CHAPTER 4 TROUBLESHOOTING IMAGE FAULTS MALFUNCTIONS 4 64 6 2 7 PCBs F04 602 06 3 11 9 9 5 13 2 7 6 10 10 8 1 12 10 4 14...
Страница 128: ......
Страница 232: ......
Страница 278: ......
Страница 326: ......
Страница 330: ......
Страница 350: ......
Страница 352: ...PRINTED IN JAPAN IMPRIME AU JAPON 0501M0 80 1 This publication is printed on 100 recycled paper...