CHAPTER 6 SELF DIAGNOSIS
6-3
1.1 Detail Codes (copier)
E000
0000
The reading of the main thermistor does not reach 30°C 1 sec after the main
power switch is turned on. Or, it does not reach 70°C 2 sec thereafter.
Main cause
The fixing film unit is faulty. The main thermistor has an open circuit. The
fixing heater has an open circuit. The main power supply PCB is faulty. The
DC controller PCB is faulty.
Caution
To reset the error, execute the following in service mode:
COPIER>FUNCTION>CLEAR>ERR.
Action
1. Connector
Is the connector of the fixing assembly connected?
a. main power supply PCB (J8) <-> relay connector <-> heater
b. DC controller PCB (J320) <-> relay connector <-> thermistor
NO:
Connect the connector.
2. Fixing film unit (thermistor)
Check the interval between pin 1 and pin 2 and between pin 3 and pin 4 of
the connectosr (4-pin) of the thermistor for electrical continuity. Is it
∞Ω
(open)?
YES: The heater has an open circuit, or the thermal switch is open. Re-
place the fixing film unit.
4. Main power supply PCB, DC controller PCB
Press the Start key. Is the drive voltage of the heater supplied by the connec-
tor J8 of the main power supply PCB?
Main heater:
between J8-1 (FSR1) and J8-5 (FSR COM)
Sub heater:
between J8-3 (FSR2) and J8-5 (FSR COM)
YES: The heater drive power supply is faulty. Replace the main power
supply PCB.
NO:
The thermistor control mechanism is faulty. Replace the DC con-
troller PCB.
Содержание iR2200 Series
Страница 18: ......
Страница 50: ...CHAPTER 4 TROUBLESHOOTING IMAGE FAULTS MALFUNCTIONS 4 4 Blank Page...
Страница 51: ......
Страница 100: ...CHAPTER 4 TROUBLESHOOTING IMAGE FAULTS MALFUNCTIONS 4 54 6 2 4 Fans F04 602 03 FM4 FM5 FM1 FM2 FM3...
Страница 110: ...CHAPTER 4 TROUBLESHOOTING IMAGE FAULTS MALFUNCTIONS 4 64 6 2 7 PCBs F04 602 06 3 11 9 9 5 13 2 7 6 10 10 8 1 12 10 4 14...
Страница 128: ......
Страница 232: ......
Страница 278: ......
Страница 326: ......
Страница 330: ......
Страница 350: ......
Страница 352: ...PRINTED IN JAPAN IMPRIME AU JAPON 0501M0 80 1 This publication is printed on 100 recycled paper...