CHAPTER 6 SELF DIAGNOSIS
6-16
E220
0001
A fault is detected on the inverter PCB for the scanning lamp.
Main cause
The inverter PCB is faulty. The reader controller PCB is faulty.
Action
1. Wiring
Is the wiring from the scanning lamp to the reader controller PCB normal?
NO:
Connect the connector firmly, and correct or replace the wiring.
2. Inverter PCB, Reader controller PCB
Try replacing the lamp inverter PCB. Is the problem corrected?
YES: End.
NO:
Replace the reader controller PCB.
E225
0000
A specific level cannot be attained for the signal during CCD gain correc-
tion at power-on.
0002
The edge gain correction level is different from the correction level for the
preceding sheet by a specific level or more.
Main cause
The scanning lamp is faulty. The CCD PCB is faulty. The rear controller
PCB is faulty.
Action
1. Scanning lamp (LAMP1)
Is the lamp ON during the initial operation after the main power switch is
turned on?
NO:
Replace the scanning lamp.
2. CCD unit, Reader controller PCB
Try replacing the CCD unit. Is the problem corrected?
YES: End.
NO:
Replace the reader controller PCB.
Содержание iR2200 Series
Страница 18: ......
Страница 50: ...CHAPTER 4 TROUBLESHOOTING IMAGE FAULTS MALFUNCTIONS 4 4 Blank Page...
Страница 51: ......
Страница 100: ...CHAPTER 4 TROUBLESHOOTING IMAGE FAULTS MALFUNCTIONS 4 54 6 2 4 Fans F04 602 03 FM4 FM5 FM1 FM2 FM3...
Страница 110: ...CHAPTER 4 TROUBLESHOOTING IMAGE FAULTS MALFUNCTIONS 4 64 6 2 7 PCBs F04 602 06 3 11 9 9 5 13 2 7 6 10 10 8 1 12 10 4 14...
Страница 128: ......
Страница 232: ......
Страница 278: ......
Страница 326: ......
Страница 330: ......
Страница 350: ......
Страница 352: ...PRINTED IN JAPAN IMPRIME AU JAPON 0501M0 80 1 This publication is printed on 100 recycled paper...