CHAPTER 5 SERVICE MODE
5-51
<HV-PRI>
Use it to adjust the output of the primary charging assembly.
If you have cleared the RAM on the DC controller PCB and replaced the PCB, be sure to
enter the setting indicated on the service label.
P-DC
Use it to enter the adjustment value for the primary charging DC component
of the image area.
Range of
0 to 255
adjustment
Caution
P-AC
Use it to enter the adjustment value for the primary charging AC component
of the image area.
Range of
0 to 255
adjustment
AGS-GAIN
Use it to adjust the gain adjustment value for the photosensitive drum resis-
tance detection control (APVC) mechanism.
Caution
If you have replaced the composite power supply PCB, be sure to enter the
settings indicated on the label attached to the new PCB (case).
Range of
0 to 255
adjustment
AGS-OFST
Use it to enter the offset adjustment value for the photosensitive drum resis-
tance detection control (APVC) mechanism.
Caution
If you have replaced the composite power supply PCB, be sure to enter the
settings indicated on the label attached to the new PCB (case).
Range of
0 to 255
adjustment
COPIER>ADJUST>HV-PRI
Содержание iR2200 Series
Страница 18: ......
Страница 50: ...CHAPTER 4 TROUBLESHOOTING IMAGE FAULTS MALFUNCTIONS 4 4 Blank Page...
Страница 51: ......
Страница 100: ...CHAPTER 4 TROUBLESHOOTING IMAGE FAULTS MALFUNCTIONS 4 54 6 2 4 Fans F04 602 03 FM4 FM5 FM1 FM2 FM3...
Страница 110: ...CHAPTER 4 TROUBLESHOOTING IMAGE FAULTS MALFUNCTIONS 4 64 6 2 7 PCBs F04 602 06 3 11 9 9 5 13 2 7 6 10 10 8 1 12 10 4 14...
Страница 128: ......
Страница 232: ......
Страница 278: ......
Страница 326: ......
Страница 330: ......
Страница 350: ......
Страница 352: ...PRINTED IN JAPAN IMPRIME AU JAPON 0501M0 80 1 This publication is printed on 100 recycled paper...