Chapter 2
2-8
F-2-31
6) Remove the developing knocking unit [1] in the direction of the arrow.
- 4 screws [2]
- 2 claws [3]
F-2-32
CAUTION:
Be sure to place the Relay Connector [2] at further rear side than the Wire
Saddle [1] when installing.
How to Install the Developing Knock Unit
1) Put the front of the developing knocking unit [1] through the opening [2]
first, then put the cable [3] through the opening [4] at the rear.
[3]
[1]
[2]
[4]
[2]
[2]
[1]
[1]
[3]
2) Fit the 2 claws [1] to position the developing knocking unit by fitting with
the 2 bosses [2].
3) While supporting the developing knocking unit [4] from below, secure it
with 4 screws (W SEMS) [3] that is included in the package.
CAUTION:
Be sure to check that the bosses [2] are securely fitted.
[1]
[2]
[3]
[4]
[3]
[3]
[4]
[1]
[1]
[2]