Chapter 2
2-68
F-2-300
2) Hook the release lever claw [2] onto the pressure plate hole [1] to lock.
F-2-301
3) Remove the 2 screws [1] and detach the outside heat pressure plate [2].
F-2-302
CAUTION:
When locking the release lever, see the long hole [3] from above to check
the pressure release support shaft [4] cannot be seen.
CAUTION:
The screw [3] on the outside heat pressure shaft MUST NOT be rotated.
[1]
[A]
[2]
[3]
[1]
[3]
[4]
[2]
Attaching External Heating Roller Unit Pressure Plate
1) Before attaching the external heating roller unit to the fixing assembly,
make almost full turn of the gear [1] counterclockwise [A] until it stops.
2) After installing the External Heating Roller Unit [1] to the Fixing
Assembly, rotate the gear [2] clockwise [B] until it stops and the Sensor Flag
[3] is at the position shown in the figure below. (The External Heating Roller
Unit is disengaged from the Fixing Roller.)
[2]
[1]
[1]
[3]
[A]
[1]