Spectrophotometer read error.
Spectrophotometer read error.
Cause
Corrective Action
The Spectrophotometer Sensor to
be loaded into the Spectrophotome-
ter Carriage is not installed correct-
ly.
Turn off the power, and reinstall by pushing the two connectors all the way into the Spectrophotometer
Sensor.
(See "Replacing the Spectrophotometer Sensor of the Spectrophotometer Unit (option).")
→P.965
The color measurement pattern
was not printed correctly.
Check the color measurement pattern. If the printing is faint, clean the printhead and perform the opera-
tion again.
(See "Cleaning the Printhead.")
→P.928
The color measurement pattern is
out of alignment.
Pulling or lifting a printed color measurement pattern may cause the pattern to come out of alignment.
Perform the operation again taking care not to touch the color measurement pattern.
Execute
Feed Priority
to improve the printing position of the pattern for color measurement.
(See "Automatic Banding Adjustment.")
→P.804
If the same message is displayed again after performing the above operation, set
Pattern Size
to
Large
on the Control Panel menu and perform the operation again.
(See "Menu Structure.")
→P.657
Alternately, it may be resolved by selecting
Air Drying
in
Drying Method
in the
Color Measurement
Preferences
dialog box in the Color Calibration Management Console and selecting the
Dry Separated
Chart
check box if it is off.
(See "Acquiring Color Measurement Data For Any Color Chart (Windows).")
→P.866
(See "Acquiring Color Measurement Data For Any Color Chart (Mac OS X).")
→P.902
The performance of part of the
Spectrophotometer Unit may be im-
paired.
Turn off the printer and wait a while before restoring power, and then perform the operation again.
If the same message is displayed again, contact your Canon dealer for assistance.
Clean calibration white tile because it may be dirty.
Clean calibration white tile because it may be dirty.
Cause
Corrective Action
The White Cali-
bration Tile may
be dirty.
Remove, clean, and reinstall the White Calibration Tile.
(See "Cleaning the Spectrophotometer Unit (option) Parts.")
→P.948
If this message is still displayed after cleaning the White Calibration Tile, we recommend adjusting the Spectrophotometer
Sensor.
Contact your Canon dealer for more information on adjustment services.
(See "Replacing the Spectrophotometer Sensor of the Spectrophotometer Unit (option).")
→P.965
iPF6450
Spectrophotometer read error.
User's Guide
Error Message
Messages regarding printing or adjustment
1025
Содержание imagePROGRAF iPF6450
Страница 20: ...20 ...
Страница 174: ...iPF6450 User s Guide 174 ...
Страница 642: ...iPF6450 User s Guide 642 ...
Страница 696: ...iPF6450 User s Guide 696 ...
Страница 730: ...iPF6450 User s Guide 730 ...
Страница 812: ...iPF6450 User s Guide 812 ...
Страница 916: ...iPF6450 User s Guide 916 ...
Страница 1055: ...iPF6450 WEEE Directive User s Guide Appendix Disposal of the product 1055 ...
Страница 1056: ...WEEE Directive iPF6450 User s Guide Appendix Disposal of the product 1056 ...
Страница 1057: ...iPF6450 WEEE Directive User s Guide Appendix Disposal of the product 1057 ...
Страница 1058: ...WEEE Directive iPF6450 User s Guide Appendix Disposal of the product 1058 ...
Страница 1059: ...iPF6450 WEEE Directive User s Guide Appendix Disposal of the product 1059 ...
Страница 1060: ...WEEE Directive iPF6450 User s Guide Appendix Disposal of the product 1060 ...
Страница 1061: ...iPF6450 WEEE Directive User s Guide Appendix Disposal of the product 1061 ...
Страница 1062: ...WEEE Directive iPF6450 User s Guide Appendix Disposal of the product 1062 ...
Страница 1065: ...1065 ...