COPYRIGHT © 1999 CANON INC.
CANON ADF FOR iR600 REV.0 JAN. 1999 PRINTED IN JAPAN (IMPRIME AU JAPON)
2-29
CHAPTER 2 OPERATIONS
Table 2-212
Figure 2-224
4.
Separation Sensor (S4), Skew Sensor (S5)
The separation sensor (S4) and the skew sensor (S5) located in the original path are used to
monitor the movement of originals for the following:
If the separation sensor does not detect an original a specific period of time after the separation
motor starts to rotate, the machine will identify the condition as being a separation error (delay).
Separation sensor (S4)
If the separation sensor does not detect
an original within a specific time,
If the separation sensor detects
an original within a specific time,
Separation sensor (S4)
Check on
Separation fault
(delay)
Original skew
Sensor (notation)
Separation sensor (S4)
Separation sensor (S4)
Skew sensor (S5)
Alarm
0031
0011