CHAPTER 3 MECHANICAL SYSTEM
3-20
COPYRIGHT © 1999 CANON INC.
CANON ADF FOR iR600 REV.0 JAN. 1999 PRINTED IN JAPAN (IMPRIME AU JAPON)
Figure 3-320
Figure 3-321
Figure 3-322
4) Remove the two screws [4], and detach the
manual feed registration sensor PCB [5].
5) Remove the grip ring [7] and the bearing
[8] from the manual feed registration roller
[6]. (delivery assembly front plate side)
6) Remove the grip ring [9] of the manual
registration roller [6] and the E-ring [11] of
the feeding belt roller shaft [10]; then, re-
move the parallel pin [13], and detach the
gear unit [14] and the bushing [15].
[4]
[5]
[7]
[6]
[8]
[10]
[15]
[14]
[11]
[9]
[6]
[13]
[12]