CHAPTER 5 TROUBLESHOOTING
5-50
COPYRIGHT © 1999 CANON INC.
CANON ADF FOR iR600 REV.0 JAN. 1999 PRINTED IN JAPAN (IMPRIME AU JAPON)
LED2 indication
0
1
2
3
4
5
6
7
Default size
A4
Non-default
LTR
Non-default
B4
Non-default
LTR
Non-default
A4
Non-default
Error*
Error
Error
Error
Error*
Error
LED2 indication
8
9
A
b
C
d
E
F
Default size
B5R
Non-default
STM
Non-default
B4
Non-default
STMT
Non-default
A5
Non-default
A5
Non-default
Error*
Error
Error*
Error
ON
Flashing
ON
Flashing
ON
Flashing
ON
Flashing
ON
Flashing
ON
Flashing
ON
Flashing
ON
Flashing
ON
Flashing
ON
Flashing
ON
Flashing
ON
Flashing
ON
Flashing
ON
Flashing
ON
Flashing
ON
Flashing
*The original detecting switch (SW301) may be faulty.
Table 5-125
4) Press the push switch (SW2) on the ADF
controller PCB once again to end the op-
eration.
2.
Initializing the Back-Up RAM
1) Remove the screw, and detach the ADF
controller cover.
2) Set the DIP switch (SW1) on the ADF
controller PCB as indicated in Figure 5-
201.
3) Press the push switch (SW2) on the ADF
controller PCB to end the operation. (The
operation will end immediately.)
Reference:
The counter data (jam, tray pickup,
manual feeder pickup) cannot be initial-
ized.
Figure 5-201
J1
J2
J5
J3
J6
J7
J8
J9
J10
J11
J14
J13
J12
J4
FU2
FU1
SW1
LED2
IC1
SW4SW3SW2
SW2
Figure 5-202