5-70
COPYRIGHT © 1999 CANON INC.
CANON ADF FOR iR600 REV.0 JAN. 1999 PRINTED IN JAPAN (IMPRIME AU JAPON)
CHAPTER 5 TROUBLESHOOTING
Functions
Indicators
Cleaning
Others
Settings
Description
Software Version Indicator
A press on the push switch (SW2) on the ADF
controller PCB will indicate the version of the
software. Another press stops the indication. (For
details, see p. 5-44.)
Cleaning the Separation Assembly
A press on the push switch (SW2) on the ADF
controller PCB will rotate the registration roller.
Another press will stop it. (For details, see p. 5-45.)
Cleaning the Registration Roller
If the dirt is limited,
Place ten sheets of copy paper on the original tray,
and press the push switch (SW2) on the ADF
controller PCB. The operation will end
automatically. (For details, see p. 5-47.)
If the dirt is excessive,
Press the push switch (SW2) on the ADF
controller PCB so that the registration roller will
rotate. Clean the roller with lint-free paper
moistened with alcohol.
To stop the operation, press the push switch (SW2)
once again. (For details, see p. 5-47.)
Checking the Original Width Detecting Switch
(SW301)
A press on the push switch (SW2) on the ADF
controller PCB will start the operation, and another
press will stop it. (For details, see p. 5-49.)
Initializing the Back-Up RAM
A press on the push switch (SW2) on the ADF
controller PCB will automatically initialize the
back-up RAM, and the operation will end
automatically.
However, note that the counter data (jam, tray
pickup, manual feeder pickup) will not be initialized.
(For details, see p. 5-50.)
Setting Mix Paper Configuration Mode
A press on the push switch (SW2) on the ADF
controller PCB will start the operation. Use the
push switch SW3 or SW4 for a switch-over. Then,
press the push switch (SW2) to store the new
setting. (For details, see p. 5-51.)
Table 5-401-4