2-25
CHAPTER 2 STANDARDS AND ADJUSTMENTS
3
Orientation of the Cleaning Belt
Mount the fixing cleaning belt as shown .
Figure 2-49 Fixing Upper Cleaning
Belt (rear view)
Figure 2-50 Fixing Lower Cleaning
Belt (rear view)
4
Orientation of the fixing Upper/
Lower Solenoid
Adjust the position so that the stroke [A]
is 3 ± 0.2 mm for the fixing paper solenoid and
4 ± 0.2 mm for the lower fixing solenoid.
Figure 2-51