G3 FACSIMILE COMMUNICATIONS
6.8.3 Details of FCF
The FCF for each signal is determined as shown in the following table.
Table 5-14 Correspondence between Signal Name and FCF
Signal
Name
FCF
Remarks
Initial identification
NSF
00000100
FIF follows right
after.
CSI
00000010
DIS
00000001
Transmit command
NSC
10000100
CIG
10000010
DTC
10000001
Receive command
NSS
X1000100
TSI
X1000010
DCS
X1000001
Pre-message responses
CFR
X0100001
FTT
X0100010
Post-message
Commands
EOM
X1110001
FIF does not fol-
low.
MPS
X1110010
EOP
X1110100
Post-message responses
MCF
X0110001
RTP
X0110011
RTN
X0110010
Others
DCN
X1011111
(Note)
According to the
ITU-T
recommendation:
The side that receives DIS first X
→
“1”
the other side X
→
“0”
that is, In regular communications:the calling side:X = 1
the called side:X = 0
In polling:
the calling side: X = 0
the called side:X = 1
• Ordinarily, X is “0” and becomes “1” when DIS is received.
This also implies protection against echo.
• X may not be a factor in cases of other manufacturer’s facsimiles.